Microfluidic Bioelectrical Impedance Drug Delivery Device for Patients with Acute Exacerbations of Chronic Obstructive Pulmonary Disease

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Carroll, Evan, Recchione, Nicholas, Henao, Jean Paul Rojas, Capone, Vincent G., D, Sleiman R. Ghorayeb Ph.
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866910712704532480
author Carroll, Evan
Recchione, Nicholas
Henao, Jean Paul Rojas
Capone, Vincent G.
D, Sleiman R. Ghorayeb Ph.
author_facet Carroll, Evan
Recchione, Nicholas
Henao, Jean Paul Rojas
Capone, Vincent G.
D, Sleiman R. Ghorayeb Ph.
contents Inhalers with corticosteroids and muscle relaxants are prescribed by pulmonologists to mitigate bronchospasms that happen due to tightening of the chest. An adhesive patch attached to a patient with chronic obstructive pulmonary disease can relieve episodes of bronchospasms in the event the prescribed inhaler is not nearby. This paper shows the design and programming created to manufacture such a device. Methods: Electrical components were connected to a 3D model created in AutoCAD Fusion 360 in the order of inches. The model was imported, and simulation tests were evaluated in COMSOL Multiphysics. The device was 3D printed in the Makerspace at Hofstra University and tested for functionality. Results: The proposed design is a macromodel prototype of the micromodel adhesive patch that will attach above the sternocleidomastoid (SCM) muscle on one side of the neck and be created in a microelectronics laboratory. Conclusion: The designed bioelectrical impedance device can detect severe muscle contractions related to the tensing and thickening of the SCM to deliver muscle relaxants to relieve acute exacerbations in patients with COPD. Significance: With this microfluidic drug delivery device even if the patient has forgotten to carry their inhaler, they are able to be relieved of the suffocating bronchospasm episode quickly and inhale their prescribed medication.
format Preprint
id arxiv_https___arxiv_org_abs_2411_15934
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Microfluidic Bioelectrical Impedance Drug Delivery Device for Patients with Acute Exacerbations of Chronic Obstructive Pulmonary Disease
Carroll, Evan
Recchione, Nicholas
Henao, Jean Paul Rojas
Capone, Vincent G.
D, Sleiman R. Ghorayeb Ph.
Medical Physics
Signal Processing
Inhalers with corticosteroids and muscle relaxants are prescribed by pulmonologists to mitigate bronchospasms that happen due to tightening of the chest. An adhesive patch attached to a patient with chronic obstructive pulmonary disease can relieve episodes of bronchospasms in the event the prescribed inhaler is not nearby. This paper shows the design and programming created to manufacture such a device. Methods: Electrical components were connected to a 3D model created in AutoCAD Fusion 360 in the order of inches. The model was imported, and simulation tests were evaluated in COMSOL Multiphysics. The device was 3D printed in the Makerspace at Hofstra University and tested for functionality. Results: The proposed design is a macromodel prototype of the micromodel adhesive patch that will attach above the sternocleidomastoid (SCM) muscle on one side of the neck and be created in a microelectronics laboratory. Conclusion: The designed bioelectrical impedance device can detect severe muscle contractions related to the tensing and thickening of the SCM to deliver muscle relaxants to relieve acute exacerbations in patients with COPD. Significance: With this microfluidic drug delivery device even if the patient has forgotten to carry their inhaler, they are able to be relieved of the suffocating bronchospasm episode quickly and inhale their prescribed medication.
title Microfluidic Bioelectrical Impedance Drug Delivery Device for Patients with Acute Exacerbations of Chronic Obstructive Pulmonary Disease
topic Medical Physics
Signal Processing
url https://arxiv.org/abs/2411.15934