Hauptverfasser: Kasper, Jonas, Awal, Awal, Hetzel, Ronja, Kołodziej, Magdalena, Rusiecka, Katarzyna, Stahl, Achim, Wong, Ming-Liang, Wrońska, Aleksandra
Format: Preprint
Veröffentlicht: 2024
Schlagworte:
Online-Zugang:https://arxiv.org/abs/2411.18239
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866912459739103232
author Kasper, Jonas
Awal, Awal
Hetzel, Ronja
Kołodziej, Magdalena
Rusiecka, Katarzyna
Stahl, Achim
Wong, Ming-Liang
Wrońska, Aleksandra
author_facet Kasper, Jonas
Awal, Awal
Hetzel, Ronja
Kołodziej, Magdalena
Rusiecka, Katarzyna
Stahl, Achim
Wong, Ming-Liang
Wrońska, Aleksandra
contents Objective: Proton therapy is a precision-focused cancer treatment where accurate proton beam range monitoring is critical to ensure effective dose delivery. This can be achieved by prompt gamma detection with a Compton camera like the SiFi-CC. This study aims to show the feasibility of optimising the geometry of SiFi-CC Compton camera for verification of dose distribution via prompt gamma detection using a genetic algorithm (GA). Approach: The SiFi-CC key geometric parameters for optimisation with the GA are the source-to-scatterer and scatterer-to-absorber distances, and the module thicknesses. The optimisation process was conducted with a software framework based on the Geant4 toolkit, which included detailed and realistic modelling of gamma interactions, detector response, and further steps such as event selection and image reconstruction. The performance of each individual configuration was evaluated using a fitness function incorporating factors related to gamma detection efficiency and image resolution. Results: The GA-optimised SiFi-CC configuration demonstrated the capability to detect a 5 mm proton beam range shift with a 2 mm resolution using 5e8 protons. The best-performing geometry, with 16 fibre layers in the scatterer, 36 layers in the absorber, source-to-scatterer distance 150 mm and scatterer-to-absorber distance 120 mm, has an imaging sensitivity of 5.58(1)e-5. Significance: This study demonstrates that the SiFi-CC setup, optimised through a GA, can reliably detect clinically relevant proton beam range shifts, improving real-time range verification accuracy in proton therapy. The presented implementation of a GA is a systematic and feasible way of searching for a SiFi-CC geometry that shows the best performance.
format Preprint
id arxiv_https___arxiv_org_abs_2411_18239
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Genetic algorithm as a tool for detection setup optimisation: SiFi-CC case study
Kasper, Jonas
Awal, Awal
Hetzel, Ronja
Kołodziej, Magdalena
Rusiecka, Katarzyna
Stahl, Achim
Wong, Ming-Liang
Wrońska, Aleksandra
Medical Physics
Instrumentation and Detectors
Objective: Proton therapy is a precision-focused cancer treatment where accurate proton beam range monitoring is critical to ensure effective dose delivery. This can be achieved by prompt gamma detection with a Compton camera like the SiFi-CC. This study aims to show the feasibility of optimising the geometry of SiFi-CC Compton camera for verification of dose distribution via prompt gamma detection using a genetic algorithm (GA). Approach: The SiFi-CC key geometric parameters for optimisation with the GA are the source-to-scatterer and scatterer-to-absorber distances, and the module thicknesses. The optimisation process was conducted with a software framework based on the Geant4 toolkit, which included detailed and realistic modelling of gamma interactions, detector response, and further steps such as event selection and image reconstruction. The performance of each individual configuration was evaluated using a fitness function incorporating factors related to gamma detection efficiency and image resolution. Results: The GA-optimised SiFi-CC configuration demonstrated the capability to detect a 5 mm proton beam range shift with a 2 mm resolution using 5e8 protons. The best-performing geometry, with 16 fibre layers in the scatterer, 36 layers in the absorber, source-to-scatterer distance 150 mm and scatterer-to-absorber distance 120 mm, has an imaging sensitivity of 5.58(1)e-5. Significance: This study demonstrates that the SiFi-CC setup, optimised through a GA, can reliably detect clinically relevant proton beam range shifts, improving real-time range verification accuracy in proton therapy. The presented implementation of a GA is a systematic and feasible way of searching for a SiFi-CC geometry that shows the best performance.
title Genetic algorithm as a tool for detection setup optimisation: SiFi-CC case study
topic Medical Physics
Instrumentation and Detectors
url https://arxiv.org/abs/2411.18239