contents A front-end readout system with a large dynamic range is required for the high-granularity crystal electromagnetic calorimeter (ECAL) at future Higgs factories. A new commercially available ASIC, MPT2321, which offers a significantly large dynamic range for the readout of the silicon photomultiplier (SiPM), has been tested in the laboratory and at a test beam facility. The fundamental performance metrics have been characterised, including response linearity, inter-calibration factor and noise performance. To quantitatively assess the dynamic range of the chip and evaluate its feasibility for SiPM readout in high-granularity crystal ECAL, a beamtest was conducted using scintillating crystals exposed to electron beams. Beamtest results showed that the chip exhibits a promising performance in terms of a good signal-to-noise ratio and a relatively large dynamic range.
format Preprint
id arxiv_https___arxiv_org_abs_2411_18927
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Lab and Beam Tests of a SiPM-readout ASIC with a Large Dynamic Range
Qi, Baohua
Liu, Yong
Shi, Huangchao
Wang, Danqi
Zhao, Zhiyu
Zhu, Hongbo
Instrumentation and Detectors
High Energy Physics - Experiment
A front-end readout system with a large dynamic range is required for the high-granularity crystal electromagnetic calorimeter (ECAL) at future Higgs factories. A new commercially available ASIC, MPT2321, which offers a significantly large dynamic range for the readout of the silicon photomultiplier (SiPM), has been tested in the laboratory and at a test beam facility. The fundamental performance metrics have been characterised, including response linearity, inter-calibration factor and noise performance. To quantitatively assess the dynamic range of the chip and evaluate its feasibility for SiPM readout in high-granularity crystal ECAL, a beamtest was conducted using scintillating crystals exposed to electron beams. Beamtest results showed that the chip exhibits a promising performance in terms of a good signal-to-noise ratio and a relatively large dynamic range.
title Lab and Beam Tests of a SiPM-readout ASIC with a Large Dynamic Range
topic Instrumentation and Detectors
High Energy Physics - Experiment
url https://arxiv.org/abs/2411.18927