Evaluating Automated Radiology Report Quality through Fine-Grained Phrasal Grounding of Clinical Findings

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Mahmood, Razi, Yan, Pingkun, Reyes, Diego Machado, Wang, Ge, Kalra, Mannudeep K., Kaviani, Parisa, Wu, Joy T., Syeda-Mahmood, Tanveer
Format: Preprint
Publié: 2024
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866908374599204864
author Mahmood, Razi
Yan, Pingkun
Reyes, Diego Machado
Wang, Ge
Kalra, Mannudeep K.
Kaviani, Parisa
Wu, Joy T.
Syeda-Mahmood, Tanveer
author_facet Mahmood, Razi
Yan, Pingkun
Reyes, Diego Machado
Wang, Ge
Kalra, Mannudeep K.
Kaviani, Parisa
Wu, Joy T.
Syeda-Mahmood, Tanveer
contents Several evaluation metrics have been developed recently to automatically assess the quality of generative AI reports for chest radiographs based only on textual information using lexical, semantic, or clinical named entity recognition methods. In this paper, we develop a new method of report quality evaluation by first extracting fine-grained finding patterns capturing the location, laterality, and severity of a large number of clinical findings. We then performed phrasal grounding to localize their associated anatomical regions on chest radiograph images. The textual and visual measures are then combined to rate the quality of the generated reports. We present results that compare this evaluation metric with other textual metrics on a gold standard dataset derived from the MIMIC collection and show its robustness and sensitivity to factual errors.
format Preprint
id arxiv_https___arxiv_org_abs_2412_01031
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Evaluating Automated Radiology Report Quality through Fine-Grained Phrasal Grounding of Clinical Findings
Mahmood, Razi
Yan, Pingkun
Reyes, Diego Machado
Wang, Ge
Kalra, Mannudeep K.
Kaviani, Parisa
Wu, Joy T.
Syeda-Mahmood, Tanveer
Computation and Language
Artificial Intelligence
Computer Vision and Pattern Recognition
Several evaluation metrics have been developed recently to automatically assess the quality of generative AI reports for chest radiographs based only on textual information using lexical, semantic, or clinical named entity recognition methods. In this paper, we develop a new method of report quality evaluation by first extracting fine-grained finding patterns capturing the location, laterality, and severity of a large number of clinical findings. We then performed phrasal grounding to localize their associated anatomical regions on chest radiograph images. The textual and visual measures are then combined to rate the quality of the generated reports. We present results that compare this evaluation metric with other textual metrics on a gold standard dataset derived from the MIMIC collection and show its robustness and sensitivity to factual errors.
title Evaluating Automated Radiology Report Quality through Fine-Grained Phrasal Grounding of Clinical Findings
topic Computation and Language
Artificial Intelligence
Computer Vision and Pattern Recognition
url https://arxiv.org/abs/2412.01031