Noninvasive In vivo Estimation of HbA1c Based on Beer Lambert Model from Photoplethysmogram Using Only Two Wavelengths

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Turja, Mrinmoy Sarker, Kwon, Tae Ho, Kim, Hyoungkeun, Kim, Ki Doo
Format: Preprint
Publié: 2024
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866913596868395008
author Turja, Mrinmoy Sarker
Kwon, Tae Ho
Kim, Hyoungkeun
Kim, Ki Doo
author_facet Turja, Mrinmoy Sarker
Kwon, Tae Ho
Kim, Hyoungkeun
Kim, Ki Doo
contents Glycated hemoglobin (HbA1c) is the most important factor in diabetes control. Since HbA1c reflects the average blood glucose level over the preceding three months, it is unaffected by the patient's activity level or diet before the test. Noninvasive HbA1c measurement reduces both the pain and complications associated with fingertip piercing to collect blood. Photoplethysmography is helpful for measuring HbA1c without blood samples. Herein, only two wavelengths (615 and 525 nm) were used to estimate HbA1c noninvasively, where two different ratio calibrations were applied and performances were compared to a work that uses three wavelengths. For the fingertip type, the Pearson r values for HbA1c estimates are 0.896 and 0.905 considering ratio calibrations for blood vessel and whole finger models, respectively. Using another value (HbA1c) calibration in addition to ratio calibrations, we can improve this performance, such that the Pearson r values of HbA1c levels are 0.929 and 0.930 for blood vessel and whole finger models, respectively. In the previous study using three wavelengths, the Pearson r values were 0.916 and 0.959 for the blood-vessel and whole-finger models, respectively. Here, the RCF of SpO2 estimation is 0.986 when SpO2 ratio calibration is applied, while in the previous study, the RCF values of SpO2 estimation were 0.983 and 0.986 for the blood-vessel and whole finger models, respectively. Thus, we show that HbA1c estimation using only two wavelengths has comparable performance to previous studies.
format Preprint
id arxiv_https___arxiv_org_abs_2412_03053
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Noninvasive In vivo Estimation of HbA1c Based on Beer Lambert Model from Photoplethysmogram Using Only Two Wavelengths
Turja, Mrinmoy Sarker
Kwon, Tae Ho
Kim, Hyoungkeun
Kim, Ki Doo
Medical Physics
Glycated hemoglobin (HbA1c) is the most important factor in diabetes control. Since HbA1c reflects the average blood glucose level over the preceding three months, it is unaffected by the patient's activity level or diet before the test. Noninvasive HbA1c measurement reduces both the pain and complications associated with fingertip piercing to collect blood. Photoplethysmography is helpful for measuring HbA1c without blood samples. Herein, only two wavelengths (615 and 525 nm) were used to estimate HbA1c noninvasively, where two different ratio calibrations were applied and performances were compared to a work that uses three wavelengths. For the fingertip type, the Pearson r values for HbA1c estimates are 0.896 and 0.905 considering ratio calibrations for blood vessel and whole finger models, respectively. Using another value (HbA1c) calibration in addition to ratio calibrations, we can improve this performance, such that the Pearson r values of HbA1c levels are 0.929 and 0.930 for blood vessel and whole finger models, respectively. In the previous study using three wavelengths, the Pearson r values were 0.916 and 0.959 for the blood-vessel and whole-finger models, respectively. Here, the RCF of SpO2 estimation is 0.986 when SpO2 ratio calibration is applied, while in the previous study, the RCF values of SpO2 estimation were 0.983 and 0.986 for the blood-vessel and whole finger models, respectively. Thus, we show that HbA1c estimation using only two wavelengths has comparable performance to previous studies.
title Noninvasive In vivo Estimation of HbA1c Based on Beer Lambert Model from Photoplethysmogram Using Only Two Wavelengths
topic Medical Physics
url https://arxiv.org/abs/2412.03053