Observation of Charge Enhancement in forward-biased neutron-irradiated 4H-SiC PiN Detectors in UV-TCT Measurements

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Gsponer, Andreas, Gaggl, Philipp, Burin, Jürgen, Waid, Simon, Bergauer, Thomas
Natura: Preprint
Pubblicazione: 2024
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866929621235138560
author Gsponer, Andreas
Gaggl, Philipp
Burin, Jürgen
Waid, Simon
Bergauer, Thomas
author_facet Gsponer, Andreas
Gaggl, Philipp
Burin, Jürgen
Waid, Simon
Bergauer, Thomas
contents Due to the increased commercial availability, wide-bandgap semiconductors and their radiation hardness have recently received increased interest from the particle physics community. 4H-Silicon Carbide (SiC), especially, is an attractive candidate for future radiation-hard detectors which do not require cooling. This paper investigates the radiation hardness of 4H-SiC p-in-n detectors irradiated up to $5\times 10^{15}$ $\text{n}_{\text{eq.}}/\text{cm}^2$ using UV-TCT. The samples have been operated in reverse and forward bias, which is possible due to the heavily decreased forward current after irradiation. Previous studies have already hinted at an excessive charge collection in forward bias, even exceeding a charge collection efficiency (CCE) of 100%. In this work, the excessive CCE in forward bias was shown to correlate heavily with the spatial profile of injected charge. For a sufficiently focused laser, the CCE starts to increase at high forward bias and even surpasses 100% instead of saturating as it does for a defocused laser beam. In reverse bias, the CCE was found to be independent of the beam spot size. For samples irradiated to high fluences ($\geq 1\times 10^{15}$ $\text{n}_{\text{eq.}}/\text{cm}^2$) the excessive CCE in forward bias is smaller and negligible at the highest fluences. Additionally, the CCE was observed to correlate to the rate of charge injection (laser pulses per second), with a logarithmic increase of the collected charge if a threshold of injected carrier density is exceeded. The mechanism of these effects is still an ongoing topic of study, however, the observations already pose implications for the accurate experimental characterization of irradiated SiC detectors.
format Preprint
id arxiv_https___arxiv_org_abs_2412_06973
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Observation of Charge Enhancement in forward-biased neutron-irradiated 4H-SiC PiN Detectors in UV-TCT Measurements
Gsponer, Andreas
Gaggl, Philipp
Burin, Jürgen
Waid, Simon
Bergauer, Thomas
Instrumentation and Detectors
Due to the increased commercial availability, wide-bandgap semiconductors and their radiation hardness have recently received increased interest from the particle physics community. 4H-Silicon Carbide (SiC), especially, is an attractive candidate for future radiation-hard detectors which do not require cooling. This paper investigates the radiation hardness of 4H-SiC p-in-n detectors irradiated up to $5\times 10^{15}$ $\text{n}_{\text{eq.}}/\text{cm}^2$ using UV-TCT. The samples have been operated in reverse and forward bias, which is possible due to the heavily decreased forward current after irradiation. Previous studies have already hinted at an excessive charge collection in forward bias, even exceeding a charge collection efficiency (CCE) of 100%. In this work, the excessive CCE in forward bias was shown to correlate heavily with the spatial profile of injected charge. For a sufficiently focused laser, the CCE starts to increase at high forward bias and even surpasses 100% instead of saturating as it does for a defocused laser beam. In reverse bias, the CCE was found to be independent of the beam spot size. For samples irradiated to high fluences ($\geq 1\times 10^{15}$ $\text{n}_{\text{eq.}}/\text{cm}^2$) the excessive CCE in forward bias is smaller and negligible at the highest fluences. Additionally, the CCE was observed to correlate to the rate of charge injection (laser pulses per second), with a logarithmic increase of the collected charge if a threshold of injected carrier density is exceeded. The mechanism of these effects is still an ongoing topic of study, however, the observations already pose implications for the accurate experimental characterization of irradiated SiC detectors.
title Observation of Charge Enhancement in forward-biased neutron-irradiated 4H-SiC PiN Detectors in UV-TCT Measurements
topic Instrumentation and Detectors
url https://arxiv.org/abs/2412.06973