Deep learning-enhanced chemiluminescence vertical flow assay for high-sensitivity cardiac troponin I testing

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Han, Gyeo-Re, Goncharov, Artem, Eryilmaz, Merve, Ye, Shun, Joung, Hyou-Arm, Ghosh, Rajesh, Ngo, Emily, Tomoeda, Aoi, Lee, Yena, Ngo, Kevin, Melton, Elizabeth, Garner, Omai B., Di Carlo, Dino, Ozcan, Aydogan
Natura: Preprint
Pubblicazione: 2024
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866929699918184448
author Han, Gyeo-Re
Goncharov, Artem
Eryilmaz, Merve
Ye, Shun
Joung, Hyou-Arm
Ghosh, Rajesh
Ngo, Emily
Tomoeda, Aoi
Lee, Yena
Ngo, Kevin
Melton, Elizabeth
Garner, Omai B.
Di Carlo, Dino
Ozcan, Aydogan
author_facet Han, Gyeo-Re
Goncharov, Artem
Eryilmaz, Merve
Ye, Shun
Joung, Hyou-Arm
Ghosh, Rajesh
Ngo, Emily
Tomoeda, Aoi
Lee, Yena
Ngo, Kevin
Melton, Elizabeth
Garner, Omai B.
Di Carlo, Dino
Ozcan, Aydogan
contents Democratizing biomarker testing at the point-of-care requires innovations that match laboratory-grade sensitivity and precision in an accessible format. Here, we demonstrate high-sensitivity detection of cardiac troponin I (cTnI) through innovations in chemiluminescence-based sensing, imaging, and deep learning-driven analysis. This chemiluminescence vertical flow assay (CL-VFA) enables rapid, low-cost, and precise quantification of cTnI, a key cardiac protein for assessing heart muscle damage and myocardial infarction. The CL-VFA integrates a user-friendly chemiluminescent paper-based sensor, a polymerized enzyme-based conjugate, a portable high-performance CL reader, and a neural network-based cTnI concentration inference algorithm. The CL-VFA measures cTnI over a broad dynamic range covering six orders of magnitude and operates with 50 uL of serum per test, delivering results in 25 min. This system achieves a detection limit of 0.16 pg/mL with an average coefficient of variation under 15%, surpassing traditional benchtop analyzers in sensitivity by an order of magnitude. In blinded validation, the computational CL-VFA accurately measured cTnI concentrations in patient samples, demonstrating a robust correlation against a clinical-grade FDA-cleared analyzer. These results highlight the potential of CL-VFA as a robust diagnostic tool for accessible, rapid cardiac biomarker testing that meets the needs of diverse healthcare settings, from emergency care to underserved regions.
format Preprint
id arxiv_https___arxiv_org_abs_2412_08945
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Deep learning-enhanced chemiluminescence vertical flow assay for high-sensitivity cardiac troponin I testing
Han, Gyeo-Re
Goncharov, Artem
Eryilmaz, Merve
Ye, Shun
Joung, Hyou-Arm
Ghosh, Rajesh
Ngo, Emily
Tomoeda, Aoi
Lee, Yena
Ngo, Kevin
Melton, Elizabeth
Garner, Omai B.
Di Carlo, Dino
Ozcan, Aydogan
Medical Physics
Applied Physics
Biological Physics
Democratizing biomarker testing at the point-of-care requires innovations that match laboratory-grade sensitivity and precision in an accessible format. Here, we demonstrate high-sensitivity detection of cardiac troponin I (cTnI) through innovations in chemiluminescence-based sensing, imaging, and deep learning-driven analysis. This chemiluminescence vertical flow assay (CL-VFA) enables rapid, low-cost, and precise quantification of cTnI, a key cardiac protein for assessing heart muscle damage and myocardial infarction. The CL-VFA integrates a user-friendly chemiluminescent paper-based sensor, a polymerized enzyme-based conjugate, a portable high-performance CL reader, and a neural network-based cTnI concentration inference algorithm. The CL-VFA measures cTnI over a broad dynamic range covering six orders of magnitude and operates with 50 uL of serum per test, delivering results in 25 min. This system achieves a detection limit of 0.16 pg/mL with an average coefficient of variation under 15%, surpassing traditional benchtop analyzers in sensitivity by an order of magnitude. In blinded validation, the computational CL-VFA accurately measured cTnI concentrations in patient samples, demonstrating a robust correlation against a clinical-grade FDA-cleared analyzer. These results highlight the potential of CL-VFA as a robust diagnostic tool for accessible, rapid cardiac biomarker testing that meets the needs of diverse healthcare settings, from emergency care to underserved regions.
title Deep learning-enhanced chemiluminescence vertical flow assay for high-sensitivity cardiac troponin I testing
topic Medical Physics
Applied Physics
Biological Physics
url https://arxiv.org/abs/2412.08945