MorphiNet: A Graph Subdivision Network for Adaptive Bi-ventricle Surface Reconstruction

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Deng, Yu, Xu, Yiyang, Qian, Linglong, Mauger, Charlène, Nasopoulou, Anastasia, Williams, Steven, Williams, Michelle, Niederer, Steven, Newby, David, McCulloch, Andrew, Omens, Jeff, Pushprajah, Kuberan, Young, Alistair
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866918303954370560
author Deng, Yu
Xu, Yiyang
Qian, Linglong
Mauger, Charlène
Nasopoulou, Anastasia
Williams, Steven
Williams, Michelle
Niederer, Steven
Newby, David
McCulloch, Andrew
Omens, Jeff
Pushprajah, Kuberan
Young, Alistair
author_facet Deng, Yu
Xu, Yiyang
Qian, Linglong
Mauger, Charlène
Nasopoulou, Anastasia
Williams, Steven
Williams, Michelle
Niederer, Steven
Newby, David
McCulloch, Andrew
Omens, Jeff
Pushprajah, Kuberan
Young, Alistair
contents Cardiac Magnetic Resonance (CMR) imaging is widely used for heart model reconstruction and digital twin computational analysis because of its ability to visualize soft tissues and capture dynamic functions. However, CMR images have an anisotropic nature, characterized by large inter-slice distances and misalignments from cardiac motion. These limitations result in data loss and measurement inaccuracies, hindering the capture of detailed anatomical structures. In this work, we introduce MorphiNet, a novel network that reproduces heart anatomy learned from high-resolution Computed Tomography (CT) images, unpaired with CMR images. MorphiNet encodes the anatomical structure as gradient fields, deforming template meshes into patient-specific geometries. A multilayer graph subdivision network refines these geometries while maintaining a dense point correspondence, suitable for computational analysis. MorphiNet achieved state-of-the-art bi-ventricular myocardium reconstruction on CMR patients with tetralogy of Fallot with 0.3 higher Dice score and 2.6 lower Hausdorff distance compared to the best existing template-based methods. While matching the anatomical fidelity of comparable neural implicit function methods, MorphiNet delivered 50$\times$ faster inference. Cross-dataset validation on the Automated Cardiac Diagnosis Challenge confirmed robust generalization, achieving a 0.7 Dice score with 30\% improvement over previous template-based approaches. We validate our anatomical learning approach through the successful restoration of missing cardiac structures and demonstrate significant improvement over standard Loop subdivision. Motion tracking experiments further confirm MorphiNet's capability for cardiac function analysis, including accurate ejection fraction calculation that correctly identifies myocardial dysfunction in tetralogy of Fallot patients.
format Preprint
id arxiv_https___arxiv_org_abs_2412_10985
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle MorphiNet: A Graph Subdivision Network for Adaptive Bi-ventricle Surface Reconstruction
Deng, Yu
Xu, Yiyang
Qian, Linglong
Mauger, Charlène
Nasopoulou, Anastasia
Williams, Steven
Williams, Michelle
Niederer, Steven
Newby, David
McCulloch, Andrew
Omens, Jeff
Pushprajah, Kuberan
Young, Alistair
Image and Video Processing
Computer Vision and Pattern Recognition
Cardiac Magnetic Resonance (CMR) imaging is widely used for heart model reconstruction and digital twin computational analysis because of its ability to visualize soft tissues and capture dynamic functions. However, CMR images have an anisotropic nature, characterized by large inter-slice distances and misalignments from cardiac motion. These limitations result in data loss and measurement inaccuracies, hindering the capture of detailed anatomical structures. In this work, we introduce MorphiNet, a novel network that reproduces heart anatomy learned from high-resolution Computed Tomography (CT) images, unpaired with CMR images. MorphiNet encodes the anatomical structure as gradient fields, deforming template meshes into patient-specific geometries. A multilayer graph subdivision network refines these geometries while maintaining a dense point correspondence, suitable for computational analysis. MorphiNet achieved state-of-the-art bi-ventricular myocardium reconstruction on CMR patients with tetralogy of Fallot with 0.3 higher Dice score and 2.6 lower Hausdorff distance compared to the best existing template-based methods. While matching the anatomical fidelity of comparable neural implicit function methods, MorphiNet delivered 50$\times$ faster inference. Cross-dataset validation on the Automated Cardiac Diagnosis Challenge confirmed robust generalization, achieving a 0.7 Dice score with 30\% improvement over previous template-based approaches. We validate our anatomical learning approach through the successful restoration of missing cardiac structures and demonstrate significant improvement over standard Loop subdivision. Motion tracking experiments further confirm MorphiNet's capability for cardiac function analysis, including accurate ejection fraction calculation that correctly identifies myocardial dysfunction in tetralogy of Fallot patients.
title MorphiNet: A Graph Subdivision Network for Adaptive Bi-ventricle Surface Reconstruction
topic Image and Video Processing
Computer Vision and Pattern Recognition
url https://arxiv.org/abs/2412.10985