Performance of an instrumented baffle placed at the entrance of Virgo's end mirror vacuum tower during O5

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Andrés-Carcasona, M., Martínez, M., Mir, Ll. M., Mundet, J., Yamamoto, H.
Formato: Preprint
Publicado: 2024
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866929683836174336
author Andrés-Carcasona, M.
Martínez, M.
Mir, Ll. M.
Mundet, J.
Yamamoto, H.
author_facet Andrés-Carcasona, M.
Martínez, M.
Mir, Ll. M.
Mundet, J.
Yamamoto, H.
contents In this article, we present results on the simulated performance of an instrumented baffle installed at the entrance of the vacuum towers hosting the end mirrors of Virgo's main Fabry-Pérot cavities. The installation of instrumented baffles is part of the Advanced Virgo Plus upgrade in time for the O5 observing run. They were originally envisaged to be suspended, mounted on new payloads and surrounding new larger end mirrors. The current Virgo upgrade plan includes the replacement of the mirrors with new ones of better quality and same dimensions, leaving the installation of new payloads and larger end mirrors to a post-O5 upgrade phase still to be defined. Here we demonstrate that placing the instrumented baffles just beyond the cryotrap gate valve and in front of the end mirrors would be equally effective for monitoring scattered light inside the cavities. This new location, more than a meter away from the mirror, further reduces the risk of contamination and any potential interference with the mirrors, preserves the full capability to monitor scattered light, and decouples the instrumented baffle timeline from the plans for installing large mirrors in the experiment. We provide an estimate of the light distribution the baffles would encounter under both nominal and non-nominal conditions, as well as an assessment of the scattered light noise introduced by these baffles in this new location, confirming that they would not compromise Virgo's sensitivity.
format Preprint
id arxiv_https___arxiv_org_abs_2412_11592
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Performance of an instrumented baffle placed at the entrance of Virgo's end mirror vacuum tower during O5
Andrés-Carcasona, M.
Martínez, M.
Mir, Ll. M.
Mundet, J.
Yamamoto, H.
Instrumentation and Detectors
In this article, we present results on the simulated performance of an instrumented baffle installed at the entrance of the vacuum towers hosting the end mirrors of Virgo's main Fabry-Pérot cavities. The installation of instrumented baffles is part of the Advanced Virgo Plus upgrade in time for the O5 observing run. They were originally envisaged to be suspended, mounted on new payloads and surrounding new larger end mirrors. The current Virgo upgrade plan includes the replacement of the mirrors with new ones of better quality and same dimensions, leaving the installation of new payloads and larger end mirrors to a post-O5 upgrade phase still to be defined. Here we demonstrate that placing the instrumented baffles just beyond the cryotrap gate valve and in front of the end mirrors would be equally effective for monitoring scattered light inside the cavities. This new location, more than a meter away from the mirror, further reduces the risk of contamination and any potential interference with the mirrors, preserves the full capability to monitor scattered light, and decouples the instrumented baffle timeline from the plans for installing large mirrors in the experiment. We provide an estimate of the light distribution the baffles would encounter under both nominal and non-nominal conditions, as well as an assessment of the scattered light noise introduced by these baffles in this new location, confirming that they would not compromise Virgo's sensitivity.
title Performance of an instrumented baffle placed at the entrance of Virgo's end mirror vacuum tower during O5
topic Instrumentation and Detectors
url https://arxiv.org/abs/2412.11592