Near Real-time Adaptive Isotropic and Anisotropic Image-to-mesh Conversion for Numerical Simulations Involving Cerebral Aneurysms

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Garner, Kevin, Drakopoulos, Fotis, Sadasivan, Chander, Chrisochoides, Nikos
Format: Preprint
Veröffentlicht: 2024
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866911300869685248
author Garner, Kevin
Drakopoulos, Fotis
Sadasivan, Chander
Chrisochoides, Nikos
author_facet Garner, Kevin
Drakopoulos, Fotis
Sadasivan, Chander
Chrisochoides, Nikos
contents Presented are two techniques that are designed to help streamline the discretization of complex vascular geometries within the numerical modeling process. The first method integrates multiple software tools into a single pipeline which can generate adaptive anisotropic meshes from segmented medical images. The pipeline is shown to satisfy quality, fidelity, smoothness, and robustness requirements while providing near real-time performance for medical image-to-mesh conversion. The second method approximates a user-defined sizing function to generate adaptive isotropic meshes of good quality and fidelity in real-time. Tested with two brain aneurysm cases and utilizing up to 96 CPU cores within a single, multicore node on Purdue University's Anvil supercomputer, the parallel adaptive anisotropic meshing method utilizes a hierarchical load balancing model (designed for large, cc-NUMA shared memory architectures) and contains an optimized local reconnection operation that performs three times faster than its original implementation from previous studies. The adaptive isotropic method is shown to generate a mesh of up to approximately 50 million elements in less than a minute while the adaptive anisotropic method is shown to generate approximately the same number of elements in about 5 minutes.
format Preprint
id arxiv_https___arxiv_org_abs_2412_13222
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Near Real-time Adaptive Isotropic and Anisotropic Image-to-mesh Conversion for Numerical Simulations Involving Cerebral Aneurysms
Garner, Kevin
Drakopoulos, Fotis
Sadasivan, Chander
Chrisochoides, Nikos
Fluid Dynamics
Distributed, Parallel, and Cluster Computing
Graphics
Mathematical Software
Numerical Analysis
Presented are two techniques that are designed to help streamline the discretization of complex vascular geometries within the numerical modeling process. The first method integrates multiple software tools into a single pipeline which can generate adaptive anisotropic meshes from segmented medical images. The pipeline is shown to satisfy quality, fidelity, smoothness, and robustness requirements while providing near real-time performance for medical image-to-mesh conversion. The second method approximates a user-defined sizing function to generate adaptive isotropic meshes of good quality and fidelity in real-time. Tested with two brain aneurysm cases and utilizing up to 96 CPU cores within a single, multicore node on Purdue University's Anvil supercomputer, the parallel adaptive anisotropic meshing method utilizes a hierarchical load balancing model (designed for large, cc-NUMA shared memory architectures) and contains an optimized local reconnection operation that performs three times faster than its original implementation from previous studies. The adaptive isotropic method is shown to generate a mesh of up to approximately 50 million elements in less than a minute while the adaptive anisotropic method is shown to generate approximately the same number of elements in about 5 minutes.
title Near Real-time Adaptive Isotropic and Anisotropic Image-to-mesh Conversion for Numerical Simulations Involving Cerebral Aneurysms
topic Fluid Dynamics
Distributed, Parallel, and Cluster Computing
Graphics
Mathematical Software
Numerical Analysis
url https://arxiv.org/abs/2412.13222