Zeptojoule Calorimetry

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Gunyhó, András, Kohvakka, Kassius, Chen, Qi-Ming, Girard, Jean-Philippe, Kokkoniemi, Roope, Liu, Wei, Möttönen, Mikko
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866913617147854848
author Gunyhó, András
Kohvakka, Kassius
Chen, Qi-Ming
Girard, Jean-Philippe
Kokkoniemi, Roope
Liu, Wei
Möttönen, Mikko
author_facet Gunyhó, András
Kohvakka, Kassius
Chen, Qi-Ming
Girard, Jean-Philippe
Kokkoniemi, Roope
Liu, Wei
Möttönen, Mikko
contents The measurement of energy is a fundamental tool used, for example, in exploring the early universe, characterizing particle decay processes, as well as in quantum technology and computing. Some of the most sensitive energy detectors are thermal, i.e., bolometers and calorimeters, which operate by absorbing incoming energy, converting it into heat, and reading out the resulting temperature change electrically using a thermometer. Extremely sensitive calorimeters, including transition edge sensors, magnetic microcalorimeters and devices based on 2D conductors such as graphene, have been shown to reach impressive energy resolutions of 17.6 zJ. Very recently superconductor--normal-conductor--superconductor (SNS) radiation sensors with metallic and graphene absorbers have resulted in predictions of full-width-at-half-maximum (FWHM) energy resolutions of 0.75 zJ and 0.05 zJ = 71 GHz$\times h$, respectively, where $h$ is the Planck constant. However, since these estimates are only mathematically extracted from steady-state noise and responsivity measurements, no calorimetry reaching single-zeptojoule energy resolution or beyond has been demonstrated. Here, we use a metallic SNS sensor to measure the energy of 1-$μ$s-long 8.4-GHz microwave pulses with a FWHM energy resolution finer than (0.95 $\pm$ 0.02) zJ = (5.9 $\pm$ 0.12) meV, corresponding to 170 photons at 8.4 GHz. The techniques of this work, combined with graphene-based sensors, provide a promising path to real-time calorimetric detection of single photons in the 10 GHz range. Such a device has potential in operating as an accurate measurement device of quantum states such as those of superconducting qubits, or used in fundamental physics explorations including quantum thermodynamics, and the search for axions.
format Preprint
id arxiv_https___arxiv_org_abs_2412_14079
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Zeptojoule Calorimetry
Gunyhó, András
Kohvakka, Kassius
Chen, Qi-Ming
Girard, Jean-Philippe
Kokkoniemi, Roope
Liu, Wei
Möttönen, Mikko
Instrumentation and Detectors
The measurement of energy is a fundamental tool used, for example, in exploring the early universe, characterizing particle decay processes, as well as in quantum technology and computing. Some of the most sensitive energy detectors are thermal, i.e., bolometers and calorimeters, which operate by absorbing incoming energy, converting it into heat, and reading out the resulting temperature change electrically using a thermometer. Extremely sensitive calorimeters, including transition edge sensors, magnetic microcalorimeters and devices based on 2D conductors such as graphene, have been shown to reach impressive energy resolutions of 17.6 zJ. Very recently superconductor--normal-conductor--superconductor (SNS) radiation sensors with metallic and graphene absorbers have resulted in predictions of full-width-at-half-maximum (FWHM) energy resolutions of 0.75 zJ and 0.05 zJ = 71 GHz$\times h$, respectively, where $h$ is the Planck constant. However, since these estimates are only mathematically extracted from steady-state noise and responsivity measurements, no calorimetry reaching single-zeptojoule energy resolution or beyond has been demonstrated. Here, we use a metallic SNS sensor to measure the energy of 1-$μ$s-long 8.4-GHz microwave pulses with a FWHM energy resolution finer than (0.95 $\pm$ 0.02) zJ = (5.9 $\pm$ 0.12) meV, corresponding to 170 photons at 8.4 GHz. The techniques of this work, combined with graphene-based sensors, provide a promising path to real-time calorimetric detection of single photons in the 10 GHz range. Such a device has potential in operating as an accurate measurement device of quantum states such as those of superconducting qubits, or used in fundamental physics explorations including quantum thermodynamics, and the search for axions.
title Zeptojoule Calorimetry
topic Instrumentation and Detectors
url https://arxiv.org/abs/2412.14079