Geant4-based technical simulation study of plastic scintillators for Positron Annihilation Lifetime Spectroscopy (PALS)

Fuente: arXiv
Saved in:
Bibliographic Details
Main Author: Boras, Dominik
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866910759232995328
author Boras, Dominik
author_facet Boras, Dominik
contents The influence of detector setup configuration and scintillator material choice on spectrum quality in Positron Annihilation Lifetime Spectroscopy (PALS) is fundamentally acknowledged primarily by empirical observation. However, this study quantifies the effects of ultra-fast plastic scintillators (BC422Q) within a conventional collinear (180-degree) detector setup used in the laboratory using the Geant4 simulation toolkit. We examine the impact of the scintillator's dimension and geometry (truncated cone vs. cylinder) on the detection efficiency for specific gamma-ray energies (1274 keV and 511 keV) and their proportion of corrupt events such as backscattering or multiple detections. Results indicate that the selection of scintillator dimension and shape significantly enhances detection efficiency albeit with an increase in corrupt events. Furthermore, we investigate the influence on the instrument response function (IRF) of the scintillators, showing how truncated cones offer superior precision and, thus, a narrower IRF compared to cylindrical shapes.
format Preprint
id arxiv_https___arxiv_org_abs_2412_17010
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Geant4-based technical simulation study of plastic scintillators for Positron Annihilation Lifetime Spectroscopy (PALS)
Boras, Dominik
Instrumentation and Detectors
Nuclear Experiment
The influence of detector setup configuration and scintillator material choice on spectrum quality in Positron Annihilation Lifetime Spectroscopy (PALS) is fundamentally acknowledged primarily by empirical observation. However, this study quantifies the effects of ultra-fast plastic scintillators (BC422Q) within a conventional collinear (180-degree) detector setup used in the laboratory using the Geant4 simulation toolkit. We examine the impact of the scintillator's dimension and geometry (truncated cone vs. cylinder) on the detection efficiency for specific gamma-ray energies (1274 keV and 511 keV) and their proportion of corrupt events such as backscattering or multiple detections. Results indicate that the selection of scintillator dimension and shape significantly enhances detection efficiency albeit with an increase in corrupt events. Furthermore, we investigate the influence on the instrument response function (IRF) of the scintillators, showing how truncated cones offer superior precision and, thus, a narrower IRF compared to cylindrical shapes.
title Geant4-based technical simulation study of plastic scintillators for Positron Annihilation Lifetime Spectroscopy (PALS)
topic Instrumentation and Detectors
Nuclear Experiment
url https://arxiv.org/abs/2412.17010