Optimizing In Vivo Data Acquisition for Robust Clinical Microvascular Imaging Using Ultrasound Localization Microscopy

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Huang, Chengwu, Lok, U-Wai, Zhang, Jingke, Zhu, Xiang Yang, Krier, James D., Stern, Amy, Knoll, Kate M., Petersen, Kendra E., Robinson, Kathryn A., Hesley, Gina K., Bentall, Andrew J., Atwell, Thomas D., Rule, Andrew D., Lerman, Lilach O., Chen, Shigao
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866909440084541440
author Huang, Chengwu
Lok, U-Wai
Zhang, Jingke
Zhu, Xiang Yang
Krier, James D.
Stern, Amy
Knoll, Kate M.
Petersen, Kendra E.
Robinson, Kathryn A.
Hesley, Gina K.
Bentall, Andrew J.
Atwell, Thomas D.
Rule, Andrew D.
Lerman, Lilach O.
Chen, Shigao
author_facet Huang, Chengwu
Lok, U-Wai
Zhang, Jingke
Zhu, Xiang Yang
Krier, James D.
Stern, Amy
Knoll, Kate M.
Petersen, Kendra E.
Robinson, Kathryn A.
Hesley, Gina K.
Bentall, Andrew J.
Atwell, Thomas D.
Rule, Andrew D.
Lerman, Lilach O.
Chen, Shigao
contents Ultrasound localization microscopy (ULM) enables microvascular imaging at spatial resolutions beyond the acoustic diffraction limit, offering significant clinical potentials. However, ULM performance relies heavily on microbubble (MB) signal sparsity, the number of detected MBs, and signal-to-noise ratio (SNR), all of which vary in clinical scenarios involving bolus MB injections. These sources of variations underscore the need to optimize MB dosage, data acquisition timing, and imaging settings in order to standardize and optimize ULM of microvasculature. This pilot study investigated temporal changes in MB signals during bolus injections in both pig and human models to optimize data acquisition for clinical ULM. Quantitative indices were developed to evaluate MB signal quality, guiding selection of acquisition timing that balances the MB localization quality and adequate MB counts. The effects of transmitted voltage and dosage were also explored. In the pig model, a relatively short window (approximately 10 seconds) for optimal acquisition was identified during the rapid wash-out phase, highlighting the need for real-time MB signal monitoring during data acquisition. The slower wash-out phase in humans allowed for a more flexible imaging window of 1-2 minutes, while trade-offs were observed between localization quality and MB density (or acquisition length) at different wash-out phase timings. Guided by these findings, robust ULM imaging was achieved in both pig and human kidneys using a short period of data acquisition, demonstrating its feasibility in clinical practice. This study provides insights into optimizing data acquisition for consistent and reproducible ULM, paving the way for its standardization and broader clinical applications.
format Preprint
id arxiv_https___arxiv_org_abs_2412_18077
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Optimizing In Vivo Data Acquisition for Robust Clinical Microvascular Imaging Using Ultrasound Localization Microscopy
Huang, Chengwu
Lok, U-Wai
Zhang, Jingke
Zhu, Xiang Yang
Krier, James D.
Stern, Amy
Knoll, Kate M.
Petersen, Kendra E.
Robinson, Kathryn A.
Hesley, Gina K.
Bentall, Andrew J.
Atwell, Thomas D.
Rule, Andrew D.
Lerman, Lilach O.
Chen, Shigao
Medical Physics
Image and Video Processing
Ultrasound localization microscopy (ULM) enables microvascular imaging at spatial resolutions beyond the acoustic diffraction limit, offering significant clinical potentials. However, ULM performance relies heavily on microbubble (MB) signal sparsity, the number of detected MBs, and signal-to-noise ratio (SNR), all of which vary in clinical scenarios involving bolus MB injections. These sources of variations underscore the need to optimize MB dosage, data acquisition timing, and imaging settings in order to standardize and optimize ULM of microvasculature. This pilot study investigated temporal changes in MB signals during bolus injections in both pig and human models to optimize data acquisition for clinical ULM. Quantitative indices were developed to evaluate MB signal quality, guiding selection of acquisition timing that balances the MB localization quality and adequate MB counts. The effects of transmitted voltage and dosage were also explored. In the pig model, a relatively short window (approximately 10 seconds) for optimal acquisition was identified during the rapid wash-out phase, highlighting the need for real-time MB signal monitoring during data acquisition. The slower wash-out phase in humans allowed for a more flexible imaging window of 1-2 minutes, while trade-offs were observed between localization quality and MB density (or acquisition length) at different wash-out phase timings. Guided by these findings, robust ULM imaging was achieved in both pig and human kidneys using a short period of data acquisition, demonstrating its feasibility in clinical practice. This study provides insights into optimizing data acquisition for consistent and reproducible ULM, paving the way for its standardization and broader clinical applications.