Improved measurements of neutron lifetime with cold neutron beam at J-PARC

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Fuwa, Y., Hasegawa, T., Hirota, K., Hoshino, T., Hosokawa, R., Ichikawa, G., Ieki, S., Ino, T., Iwashita, Y., Kitaguchi, M., Kitahara, R., Makise, S., Mishima, K., Mogi, T., Nagakura, N., Oide, H., Okabe, H., Otono, H., Seki, Y., Sekiba, D., Shima, T., Shimizu, H. E., Shimizu, H. M., Sumi, N., Sumino, H., Tanida, M., Uehara, H., Yamada, T., Yamashita, S., Yano, K., Yoshioka, T.
Formato: Preprint
Publicado: 2024
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866912170386653184
author Fuwa, Y.
Hasegawa, T.
Hirota, K.
Hoshino, T.
Hosokawa, R.
Ichikawa, G.
Ieki, S.
Ino, T.
Iwashita, Y.
Kitaguchi, M.
Kitahara, R.
Makise, S.
Mishima, K.
Mogi, T.
Nagakura, N.
Oide, H.
Okabe, H.
Otono, H.
Seki, Y.
Sekiba, D.
Shima, T.
Shimizu, H. E.
Shimizu, H. M.
Sumi, N.
Sumino, H.
Tanida, M.
Uehara, H.
Yamada, T.
Yamashita, S.
Yano, K.
Yoshioka, T.
author_facet Fuwa, Y.
Hasegawa, T.
Hirota, K.
Hoshino, T.
Hosokawa, R.
Ichikawa, G.
Ieki, S.
Ino, T.
Iwashita, Y.
Kitaguchi, M.
Kitahara, R.
Makise, S.
Mishima, K.
Mogi, T.
Nagakura, N.
Oide, H.
Okabe, H.
Otono, H.
Seki, Y.
Sekiba, D.
Shima, T.
Shimizu, H. E.
Shimizu, H. M.
Sumi, N.
Sumino, H.
Tanida, M.
Uehara, H.
Yamada, T.
Yamashita, S.
Yano, K.
Yoshioka, T.
contents The ``neutron lifetime puzzle'' arises from the discrepancy between neutron lifetime measurements obtained using the beam method, which measures decay products, and the bottle method, which measures the disappearance of neutrons. To resolve this puzzle, we conducted an experiment using a pulsed cold neutron beam at J-PARC. In this experiment, the neutron lifetime is determined from the ratio of neutron decay counts to $^3$He(n,p)$^3$H reactions in a gas detector. This experiment belongs to the beam method but differs from previous experiments that measured protons, as it instead detects electrons, enabling measurements with distinct systematic uncertainties. By enlarging the beam transport system and reducing systematic uncertainties, we achieved a fivefold improvement in precision. Analysis of all acquired data yielded a neutron lifetime of $τ_{\rm n}=877.2~\pm~1.7_{\rm(stat.)}~^{+4.0}_{-3.6}{}_{\rm (sys.)}$ s. This result is consistent with bottle method measurements but exhibits a 2.3$σ$ tension with the average value obtained from the proton-detection-based beam method.
format Preprint
id arxiv_https___arxiv_org_abs_2412_19519
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Improved measurements of neutron lifetime with cold neutron beam at J-PARC
Fuwa, Y.
Hasegawa, T.
Hirota, K.
Hoshino, T.
Hosokawa, R.
Ichikawa, G.
Ieki, S.
Ino, T.
Iwashita, Y.
Kitaguchi, M.
Kitahara, R.
Makise, S.
Mishima, K.
Mogi, T.
Nagakura, N.
Oide, H.
Okabe, H.
Otono, H.
Seki, Y.
Sekiba, D.
Shima, T.
Shimizu, H. E.
Shimizu, H. M.
Sumi, N.
Sumino, H.
Tanida, M.
Uehara, H.
Yamada, T.
Yamashita, S.
Yano, K.
Yoshioka, T.
Nuclear Experiment
High Energy Physics - Experiment
The ``neutron lifetime puzzle'' arises from the discrepancy between neutron lifetime measurements obtained using the beam method, which measures decay products, and the bottle method, which measures the disappearance of neutrons. To resolve this puzzle, we conducted an experiment using a pulsed cold neutron beam at J-PARC. In this experiment, the neutron lifetime is determined from the ratio of neutron decay counts to $^3$He(n,p)$^3$H reactions in a gas detector. This experiment belongs to the beam method but differs from previous experiments that measured protons, as it instead detects electrons, enabling measurements with distinct systematic uncertainties. By enlarging the beam transport system and reducing systematic uncertainties, we achieved a fivefold improvement in precision. Analysis of all acquired data yielded a neutron lifetime of $τ_{\rm n}=877.2~\pm~1.7_{\rm(stat.)}~^{+4.0}_{-3.6}{}_{\rm (sys.)}$ s. This result is consistent with bottle method measurements but exhibits a 2.3$σ$ tension with the average value obtained from the proton-detection-based beam method.
title Improved measurements of neutron lifetime with cold neutron beam at J-PARC
topic Nuclear Experiment
High Energy Physics - Experiment
url https://arxiv.org/abs/2412.19519