High performance Black Phosphorus/Graphitic Carbon Nitride Heterostructure-based Wearable Sensor for Real-time Sweat Glucose Monitoring

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Ozkahraman, Ecem Ezgi, Eroglu, Zafer, Efremov, Vladimir, Maryyam, Arooba, Abbasiasl, Taher, Das, Ritu, Mirzajani, Hadi, Hanedar, Berna Akgenc, Beker, Levent, Metin, Onder
Format: Preprint
Publié: 2024
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866910764924665856
author Ozkahraman, Ecem Ezgi
Eroglu, Zafer
Efremov, Vladimir
Maryyam, Arooba
Abbasiasl, Taher
Das, Ritu
Mirzajani, Hadi
Hanedar, Berna Akgenc
Beker, Levent
Metin, Onder
author_facet Ozkahraman, Ecem Ezgi
Eroglu, Zafer
Efremov, Vladimir
Maryyam, Arooba
Abbasiasl, Taher
Das, Ritu
Mirzajani, Hadi
Hanedar, Berna Akgenc
Beker, Levent
Metin, Onder
contents Wearable, non-invasive glucose sensors capable of accurate and continuous monitoring are crucial for managing metabolic conditions yet achieving high sensitivity and stability in these devices remains challenging. In this work, we present a Black Phosphorus/Graphitic Carbon Nitride (BP/g-CN) heterostructure engineered to leverage phosphorus-nitrogen interactions for enhanced electrochemical glucose oxidation activity. Compared to pristine gCN, the BP-gCN heterostructure demonstrates a significantly improved electrochemical surface area (ECSA) and nearly two-fold reduction in charge transfer resistance (Rct), achieving remarkable glucose sensitivity of 1.1 uA mM(^-1) cm(^-2) at physiological pH. Density functional theory (DFT) calculations revealed stronger glucose adsorption and higher charge transfer on the BP-gCN heterostructure compared to pristine gCN surface. These theoretical insights complement the experimental findings, highlighting the superior electrocatalytic performance of the heterostructure and the role of oxidized BP surface. Furthermore, the BP-gCN sensor is integrated into a wearable device platform with microfluidic layers and a Near Field Communication (NFC) chip, forming a conformal skin patch that enables real-time sweat glucose monitoring. This demonstration of a high-performance, non-enzymatic wearable glucose sensor based on a heterostructure design underscores the potential of the device for seamless health management and paves the way for next generation biosensing platforms aimed at improving personalized and continuous health monitoring.
format Preprint
id arxiv_https___arxiv_org_abs_2412_19633
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle High performance Black Phosphorus/Graphitic Carbon Nitride Heterostructure-based Wearable Sensor for Real-time Sweat Glucose Monitoring
Ozkahraman, Ecem Ezgi
Eroglu, Zafer
Efremov, Vladimir
Maryyam, Arooba
Abbasiasl, Taher
Das, Ritu
Mirzajani, Hadi
Hanedar, Berna Akgenc
Beker, Levent
Metin, Onder
Medical Physics
Materials Science
Applied Physics
Wearable, non-invasive glucose sensors capable of accurate and continuous monitoring are crucial for managing metabolic conditions yet achieving high sensitivity and stability in these devices remains challenging. In this work, we present a Black Phosphorus/Graphitic Carbon Nitride (BP/g-CN) heterostructure engineered to leverage phosphorus-nitrogen interactions for enhanced electrochemical glucose oxidation activity. Compared to pristine gCN, the BP-gCN heterostructure demonstrates a significantly improved electrochemical surface area (ECSA) and nearly two-fold reduction in charge transfer resistance (Rct), achieving remarkable glucose sensitivity of 1.1 uA mM(^-1) cm(^-2) at physiological pH. Density functional theory (DFT) calculations revealed stronger glucose adsorption and higher charge transfer on the BP-gCN heterostructure compared to pristine gCN surface. These theoretical insights complement the experimental findings, highlighting the superior electrocatalytic performance of the heterostructure and the role of oxidized BP surface. Furthermore, the BP-gCN sensor is integrated into a wearable device platform with microfluidic layers and a Near Field Communication (NFC) chip, forming a conformal skin patch that enables real-time sweat glucose monitoring. This demonstration of a high-performance, non-enzymatic wearable glucose sensor based on a heterostructure design underscores the potential of the device for seamless health management and paves the way for next generation biosensing platforms aimed at improving personalized and continuous health monitoring.
title High performance Black Phosphorus/Graphitic Carbon Nitride Heterostructure-based Wearable Sensor for Real-time Sweat Glucose Monitoring
topic Medical Physics
Materials Science
Applied Physics
url https://arxiv.org/abs/2412.19633