Calorimetric Wire Detector for Measurement of Atomic Hydrogen Beams
Fuente:
arXiv
Enregistré dans:
| Auteurs principaux: | , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , |
|---|---|
| Format: | Preprint |
| Publié: |
2025
|
| Sujets: | |
| Accès en ligne: | |
| Tags: |
Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
|
| _version_ | 1866915193621053440 |
|---|---|
| author | Astaschov, M. Bhagvati, S. Böser, S. Brandsema, M. J. Cabral, R. Claessens, C. de Viveiros, L. Enomoto, S. Fenner, D. Fertl, M. Formaggio, J. A. Foust, B. T. Gaison, J. K. Harmston, P. Heeger, K. M. Hüneborn, M. B. Huyan, X. Jones, A. M. Jones, B. J. P. Karim, E. Kazkaz, K. Kern, P. Li, M. Lindman, A. Liu, C. -Y. Marsteller, A. Matthé, C. Mohiuddin, R. Monreal, B. Mucogllava, B. Mueller, R. Negi, A. Nikkel, J. A. Oblath, N. S. Oueslati, M. Peña, J. I. Pettus, W. Reimann, R. Reine, A. L. Robertson, R. G. H. De Jesús, D. Rosa Saldaña, L. Slocum, P. L. Spanier, F. Stachurska, J. Sun, Y. -H. Surukuchi, P. T. Telles, A. B. Thomas, F. Thorne, L. A. Thümmler, T. Van De Pontseele, W. VanDevender, B. A. Weiss, T. E. Wynne, M. Ziegler, A. |
| author_facet | Astaschov, M. Bhagvati, S. Böser, S. Brandsema, M. J. Cabral, R. Claessens, C. de Viveiros, L. Enomoto, S. Fenner, D. Fertl, M. Formaggio, J. A. Foust, B. T. Gaison, J. K. Harmston, P. Heeger, K. M. Hüneborn, M. B. Huyan, X. Jones, A. M. Jones, B. J. P. Karim, E. Kazkaz, K. Kern, P. Li, M. Lindman, A. Liu, C. -Y. Marsteller, A. Matthé, C. Mohiuddin, R. Monreal, B. Mucogllava, B. Mueller, R. Negi, A. Nikkel, J. A. Oblath, N. S. Oueslati, M. Peña, J. I. Pettus, W. Reimann, R. Reine, A. L. Robertson, R. G. H. De Jesús, D. Rosa Saldaña, L. Slocum, P. L. Spanier, F. Stachurska, J. Sun, Y. -H. Surukuchi, P. T. Telles, A. B. Thomas, F. Thorne, L. A. Thümmler, T. Van De Pontseele, W. VanDevender, B. A. Weiss, T. E. Wynne, M. Ziegler, A. |
| contents | A calorimetric detector for minimally disruptive measurements of atomic hydrogen beams is described. The calorimeter measures heat released by the recombination of hydrogen atoms into molecules on a thin wire. As a demonstration, the angular distribution of a beam with a peak intensity of $\approx 10^{16} \,{\rm{atoms}}/{(\rm{cm}^2 \rm{s})}$ is measured by translating the wire across the beam. The data agree well with an analytic model of the beam from the thermal hydrogen atom source. Using the beam shape model, the relative intensity of the beam can be determined to 5% precision or better at any angle. |
| format | Preprint |
| id |
arxiv_https___arxiv_org_abs_2501_01268 |
| institution | arXiv |
| publishDate | 2025 |
| record_format | arxiv |
| spellingShingle | Calorimetric Wire Detector for Measurement of Atomic Hydrogen Beams Astaschov, M. Bhagvati, S. Böser, S. Brandsema, M. J. Cabral, R. Claessens, C. de Viveiros, L. Enomoto, S. Fenner, D. Fertl, M. Formaggio, J. A. Foust, B. T. Gaison, J. K. Harmston, P. Heeger, K. M. Hüneborn, M. B. Huyan, X. Jones, A. M. Jones, B. J. P. Karim, E. Kazkaz, K. Kern, P. Li, M. Lindman, A. Liu, C. -Y. Marsteller, A. Matthé, C. Mohiuddin, R. Monreal, B. Mucogllava, B. Mueller, R. Negi, A. Nikkel, J. A. Oblath, N. S. Oueslati, M. Peña, J. I. Pettus, W. Reimann, R. Reine, A. L. Robertson, R. G. H. De Jesús, D. Rosa Saldaña, L. Slocum, P. L. Spanier, F. Stachurska, J. Sun, Y. -H. Surukuchi, P. T. Telles, A. B. Thomas, F. Thorne, L. A. Thümmler, T. Van De Pontseele, W. VanDevender, B. A. Weiss, T. E. Wynne, M. Ziegler, A. Instrumentation and Detectors A calorimetric detector for minimally disruptive measurements of atomic hydrogen beams is described. The calorimeter measures heat released by the recombination of hydrogen atoms into molecules on a thin wire. As a demonstration, the angular distribution of a beam with a peak intensity of $\approx 10^{16} \,{\rm{atoms}}/{(\rm{cm}^2 \rm{s})}$ is measured by translating the wire across the beam. The data agree well with an analytic model of the beam from the thermal hydrogen atom source. Using the beam shape model, the relative intensity of the beam can be determined to 5% precision or better at any angle. |
| title | Calorimetric Wire Detector for Measurement of Atomic Hydrogen Beams |
| topic | Instrumentation and Detectors |
| url | https://arxiv.org/abs/2501.01268 |