Estimation of 3T MR images from 1.5T images regularized with Physics based Constraint

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Kaur, Prabhjot, Minhas, Atul Singh, Ahuja, Chirag Kamal, Sao, Anil Kumar
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866909447518945280
author Kaur, Prabhjot
Minhas, Atul Singh
Ahuja, Chirag Kamal
Sao, Anil Kumar
author_facet Kaur, Prabhjot
Minhas, Atul Singh
Ahuja, Chirag Kamal
Sao, Anil Kumar
contents Limited accessibility to high field MRI scanners (such as 7T, 11T) has motivated the development of post-processing methods to improve low field images. Several existing post-processing methods have shown the feasibility to improve 3T images to produce 7T-like images [3,18]. It has been observed that improving lower field (LF, <=1.5T) images comes with additional challenges due to poor image quality such as the function mapping 1.5T and higher field (HF, 3T) images is more complex than the function relating 3T and 7T images [10]. Except for [10], no method has been addressed to improve <=1.5T MRI images. Further, most of the existing methods [3,18] including [10] require example images, and also often rely on pixel to pixel correspondences between LF and HF images which are usually inaccurate for <=1.5T images. The focus of this paper is to address the unsupervised framework for quality improvement of 1.5T images and avoid the expensive requirements of example images and associated image registration. The LF and HF images are assumed to be related by a linear transformation (LT). The unknown HF image and unknown LT are estimated in alternate minimization framework. Further, a physics based constraint is proposed that provides an additional non-linear function relating LF and HF images in order to achieve the desired high contrast in estimated HF image. The experimental results demonstrate that the proposed approach provides processed 1.5T images, i.e., estimated 3T-like images with improved image quality, and is comparably better than the existing methods addressing similar problems. The improvement in image quality is also shown to provide better tissue segmentation and volume quantification as compared to scanner acquired 1.5T images.
format Preprint
id arxiv_https___arxiv_org_abs_2501_01464
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Estimation of 3T MR images from 1.5T images regularized with Physics based Constraint
Kaur, Prabhjot
Minhas, Atul Singh
Ahuja, Chirag Kamal
Sao, Anil Kumar
Image and Video Processing
Computer Vision and Pattern Recognition
Machine Learning
Medical Physics
Limited accessibility to high field MRI scanners (such as 7T, 11T) has motivated the development of post-processing methods to improve low field images. Several existing post-processing methods have shown the feasibility to improve 3T images to produce 7T-like images [3,18]. It has been observed that improving lower field (LF, <=1.5T) images comes with additional challenges due to poor image quality such as the function mapping 1.5T and higher field (HF, 3T) images is more complex than the function relating 3T and 7T images [10]. Except for [10], no method has been addressed to improve <=1.5T MRI images. Further, most of the existing methods [3,18] including [10] require example images, and also often rely on pixel to pixel correspondences between LF and HF images which are usually inaccurate for <=1.5T images. The focus of this paper is to address the unsupervised framework for quality improvement of 1.5T images and avoid the expensive requirements of example images and associated image registration. The LF and HF images are assumed to be related by a linear transformation (LT). The unknown HF image and unknown LT are estimated in alternate minimization framework. Further, a physics based constraint is proposed that provides an additional non-linear function relating LF and HF images in order to achieve the desired high contrast in estimated HF image. The experimental results demonstrate that the proposed approach provides processed 1.5T images, i.e., estimated 3T-like images with improved image quality, and is comparably better than the existing methods addressing similar problems. The improvement in image quality is also shown to provide better tissue segmentation and volume quantification as compared to scanner acquired 1.5T images.
title Estimation of 3T MR images from 1.5T images regularized with Physics based Constraint
topic Image and Video Processing
Computer Vision and Pattern Recognition
Machine Learning
Medical Physics
url https://arxiv.org/abs/2501.01464