Equipoise calibration of clinical trial design

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autor principal: Rigat, Fabio
Formato: Preprint
Publicado: 2025
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866914385305272320
author Rigat, Fabio
author_facet Rigat, Fabio
contents Clinical trial design ensures that primary analysis outcomes have strong statistical properties. However, mainstream methodology for randomised study design does not establish a formal link between statistical and clinical significance. This paper contributes to bridging this gap by calibrating the operational characteristics of primary trial outcomes to establishing clinical equipoise imbalance. Common late phase designs are shown to provide at least 90% evidence of equipoise imbalance. Designs carrying 95% power at 5% false positive rate are shown to demonstrate 95% evidence of equipoise imbalance, providing an operational definition of a robustly powered study. Equipoise calibration is applied to design of clinical development plans comprising phase 2 and phase 3 studies using standard oncology endpoints. Commonly used power and false positive error rates are shown to provide strong equipoise imbalance when positive outcomes are observed in both phase 2 and phase 3. Establishing strong equipoise imbalance based on inconsistent outcomes of phase 2 and phase 3 studies is shown to require large sample sizes unlikely to be associated with clinically meaningful effect sizes.
format Preprint
id arxiv_https___arxiv_org_abs_2501_03009
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Equipoise calibration of clinical trial design
Rigat, Fabio
Applications
Clinical trial design ensures that primary analysis outcomes have strong statistical properties. However, mainstream methodology for randomised study design does not establish a formal link between statistical and clinical significance. This paper contributes to bridging this gap by calibrating the operational characteristics of primary trial outcomes to establishing clinical equipoise imbalance. Common late phase designs are shown to provide at least 90% evidence of equipoise imbalance. Designs carrying 95% power at 5% false positive rate are shown to demonstrate 95% evidence of equipoise imbalance, providing an operational definition of a robustly powered study. Equipoise calibration is applied to design of clinical development plans comprising phase 2 and phase 3 studies using standard oncology endpoints. Commonly used power and false positive error rates are shown to provide strong equipoise imbalance when positive outcomes are observed in both phase 2 and phase 3. Establishing strong equipoise imbalance based on inconsistent outcomes of phase 2 and phase 3 studies is shown to require large sample sizes unlikely to be associated with clinically meaningful effect sizes.
title Equipoise calibration of clinical trial design
topic Applications
url https://arxiv.org/abs/2501.03009