3D Single-shot CEST imaging at 3T Based on True FISP Readout

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Wu, Yupeng, Pang, Qifan, Wang, Zhichao, Li, Gaiying, Fu, Caixia, Cao, Mengqiu, Wang, Xingrui, Jiang, Dongmei, She, Dejun, Song, Yang, Zhao, Yu, Li, Jianqi
Format: Preprint
Veröffentlicht: 2025
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866912503474159616
author Wu, Yupeng
Pang, Qifan
Wang, Zhichao
Li, Gaiying
Fu, Caixia
Cao, Mengqiu
Wang, Xingrui
Jiang, Dongmei
She, Dejun
Song, Yang
Zhao, Yu
Li, Jianqi
author_facet Wu, Yupeng
Pang, Qifan
Wang, Zhichao
Li, Gaiying
Fu, Caixia
Cao, Mengqiu
Wang, Xingrui
Jiang, Dongmei
She, Dejun
Song, Yang
Zhao, Yu
Li, Jianqi
contents To simultaneously fit multiple-pool effects, spectrally selective 3D CEST imaging typically requires single-shot readouts to save time. However, to date, FLASH and EPI have been the primary pulse sequences used for this purpose. They suffer from low SNR or image distortion related to B0 field inhomogeneity. In this work, we developed a 3D single-shot CEST sequence using true fast imaging with steady-state precession (True FISP) readout, also known as bSSFP, and optimized the scanning parameters through simulations. The performance of the CEST sequence was validated using an egg white phantom, ten healthy volunteers, and a patient with a brain tumor on a 3T human scanner. Subsequently, the proposed CEST sequence using True FISP was compared with the commonly used FLASH-based CEST sequence, focusing on SNR and image contrast, while maintaining identical pre-saturation modes, repetition time, echo time and scan time. In the simulation experiments, the maximum CEST signal obtained from the True FISP was significantly greater than that obtained from the FLASH sequence. In the egg white phantom, the SNRs of amide proton transfer (APT) and nuclear Overhauser enhancement (NOE) effect images obtained from the True FISP were 68.3% and 57.0% higher than those obtained from the FLASH sequence, respectively. In healthy volunteers, saturated images collected with the True FISP sequence at 3.5 ppm showed an approximate 84% increase in mean temporal SNR compared to those collected with the FLASH sequence. Compared to the FLASH sequence, the CEST images obtained from the True FISP sequence could display more detailed brain tissue structures of both normal individuals and the patient with a brain tumor. Therefore, due to the high SNR inherent in the sequence, True FISP has the potential to be used for fast and high-quality 3D image readout of CEST contrasts in clinical applications.
format Preprint
id arxiv_https___arxiv_org_abs_2501_03548
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle 3D Single-shot CEST imaging at 3T Based on True FISP Readout
Wu, Yupeng
Pang, Qifan
Wang, Zhichao
Li, Gaiying
Fu, Caixia
Cao, Mengqiu
Wang, Xingrui
Jiang, Dongmei
She, Dejun
Song, Yang
Zhao, Yu
Li, Jianqi
Medical Physics
To simultaneously fit multiple-pool effects, spectrally selective 3D CEST imaging typically requires single-shot readouts to save time. However, to date, FLASH and EPI have been the primary pulse sequences used for this purpose. They suffer from low SNR or image distortion related to B0 field inhomogeneity. In this work, we developed a 3D single-shot CEST sequence using true fast imaging with steady-state precession (True FISP) readout, also known as bSSFP, and optimized the scanning parameters through simulations. The performance of the CEST sequence was validated using an egg white phantom, ten healthy volunteers, and a patient with a brain tumor on a 3T human scanner. Subsequently, the proposed CEST sequence using True FISP was compared with the commonly used FLASH-based CEST sequence, focusing on SNR and image contrast, while maintaining identical pre-saturation modes, repetition time, echo time and scan time. In the simulation experiments, the maximum CEST signal obtained from the True FISP was significantly greater than that obtained from the FLASH sequence. In the egg white phantom, the SNRs of amide proton transfer (APT) and nuclear Overhauser enhancement (NOE) effect images obtained from the True FISP were 68.3% and 57.0% higher than those obtained from the FLASH sequence, respectively. In healthy volunteers, saturated images collected with the True FISP sequence at 3.5 ppm showed an approximate 84% increase in mean temporal SNR compared to those collected with the FLASH sequence. Compared to the FLASH sequence, the CEST images obtained from the True FISP sequence could display more detailed brain tissue structures of both normal individuals and the patient with a brain tumor. Therefore, due to the high SNR inherent in the sequence, True FISP has the potential to be used for fast and high-quality 3D image readout of CEST contrasts in clinical applications.
title 3D Single-shot CEST imaging at 3T Based on True FISP Readout
topic Medical Physics
url https://arxiv.org/abs/2501.03548