Guardado en:
Detalles Bibliográficos
Autores principales: Yaldiz, Hilal Esra, Akan, Ozgur B.
Formato: Preprint
Publicado: 2025
Materias:
Acceso en línea:https://arxiv.org/abs/2501.06092
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866917889201668096
author Yaldiz, Hilal Esra
Akan, Ozgur B.
author_facet Yaldiz, Hilal Esra
Akan, Ozgur B.
contents This study proposes a novel molecular communication (MC)-inspired nanomachine, PArticle COllector-Transmitter (PaCoT), to remove toxic heavy metals from the human circulatory system. PaCoT collects these toxic metals and transmits them to release nodes, such as lymph capillaries, before they reach critical organs. The design incorporates key physical parameters and operates through particle reception and release mechanisms. In the reception process, described as ligand-receptor binding reactions, modeled as a continuous-time Markov process (CTMP), PaCoT uses metallothionein proteins as receptors and heavy metals (e.g., Zn, Pb, Cd) as ligands. We assume that the toxicity condition (toxic (bit-1), non-toxic (bit-0)) is encoded into the concentration of heavy metal molecules. Thus, we consider that heavy metal concentration within the MC channel (e.g., human circulatory system) employs binary concentration shift keying (binary CSK). The concentration ratio of specific heavy metals is estimated to infer toxicity, i.e., a high ratio indicates toxicity and a low ratio suggests non-toxicity. Toxicity detection is achieved by monitoring the receptor bound duration in the presence of interferers and various types of heavy metals. After detecting and collecting toxic heavy metals, PaCoT securely retains them in a liquid medium (e.g., water) until release, employing two mechanisms: (1) a single-disc viscous micropump to regulate flow rate, and (2) Brownian motion to facilitate diffusion. PaCoT's performance is evaluated through MATLAB simulations, focusing on bit error probability (BEP) of the toxicity detection method, release time of molecules from PaCoT and energy consumption.
format Preprint
id arxiv_https___arxiv_org_abs_2501_06092
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Molecular Communication-Inspired Particle Collector-Transmitter (PaCoT) for Heavy Metal Removal from Human Circulatory System
Yaldiz, Hilal Esra
Akan, Ozgur B.
Systems and Control
This study proposes a novel molecular communication (MC)-inspired nanomachine, PArticle COllector-Transmitter (PaCoT), to remove toxic heavy metals from the human circulatory system. PaCoT collects these toxic metals and transmits them to release nodes, such as lymph capillaries, before they reach critical organs. The design incorporates key physical parameters and operates through particle reception and release mechanisms. In the reception process, described as ligand-receptor binding reactions, modeled as a continuous-time Markov process (CTMP), PaCoT uses metallothionein proteins as receptors and heavy metals (e.g., Zn, Pb, Cd) as ligands. We assume that the toxicity condition (toxic (bit-1), non-toxic (bit-0)) is encoded into the concentration of heavy metal molecules. Thus, we consider that heavy metal concentration within the MC channel (e.g., human circulatory system) employs binary concentration shift keying (binary CSK). The concentration ratio of specific heavy metals is estimated to infer toxicity, i.e., a high ratio indicates toxicity and a low ratio suggests non-toxicity. Toxicity detection is achieved by monitoring the receptor bound duration in the presence of interferers and various types of heavy metals. After detecting and collecting toxic heavy metals, PaCoT securely retains them in a liquid medium (e.g., water) until release, employing two mechanisms: (1) a single-disc viscous micropump to regulate flow rate, and (2) Brownian motion to facilitate diffusion. PaCoT's performance is evaluated through MATLAB simulations, focusing on bit error probability (BEP) of the toxicity detection method, release time of molecules from PaCoT and energy consumption.
title Molecular Communication-Inspired Particle Collector-Transmitter (PaCoT) for Heavy Metal Removal from Human Circulatory System
topic Systems and Control
url https://arxiv.org/abs/2501.06092