Enregistré dans:
Détails bibliographiques
Auteur principal: Becker, Jan
Format: Preprint
Publié: 2025
Sujets:
Accès en ligne:https://arxiv.org/abs/2501.06344
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866915098803568640
author Becker, Jan
author_facet Becker, Jan
contents The precise optical, label-free, measurement of mass at the nanoscale has been significantly advanced by techniques based on interferometric scattering, such as mass photometry (MP). These methods exploit the interference between a scattered and reference field to achieve a high signal-to-noise ratio (SNR) for weakly scattering objects (e.g. proteins) and are currently limited to masses bigger than 40 kDa. Standard MP employs a mask that attenuates the reference field, allowing for the increase in illumination power without saturation of the detector. In this theoretical study, we examine how the SNR evolves when extending reference attenuation beyond conventional levels: entering the low-reference regime. Our simplified model finds that a substantial SNR enhancement can be achieved when the magnitude of reference matches that of the scattered field and investigate refractive index tuning as a potential method to reach the required attenuation in practice. The accomplishable SNR improvement can be tailored to a given mass region, i.e. allowing the detection of masses smaller than 40 kDa.
format Preprint
id arxiv_https___arxiv_org_abs_2501_06344
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Interferometric optical mass measurement in the low-reference regime
Becker, Jan
Optics
Biological Physics
The precise optical, label-free, measurement of mass at the nanoscale has been significantly advanced by techniques based on interferometric scattering, such as mass photometry (MP). These methods exploit the interference between a scattered and reference field to achieve a high signal-to-noise ratio (SNR) for weakly scattering objects (e.g. proteins) and are currently limited to masses bigger than 40 kDa. Standard MP employs a mask that attenuates the reference field, allowing for the increase in illumination power without saturation of the detector. In this theoretical study, we examine how the SNR evolves when extending reference attenuation beyond conventional levels: entering the low-reference regime. Our simplified model finds that a substantial SNR enhancement can be achieved when the magnitude of reference matches that of the scattered field and investigate refractive index tuning as a potential method to reach the required attenuation in practice. The accomplishable SNR improvement can be tailored to a given mass region, i.e. allowing the detection of masses smaller than 40 kDa.
title Interferometric optical mass measurement in the low-reference regime
topic Optics
Biological Physics
url https://arxiv.org/abs/2501.06344