Novel Silicon and GaAs Sensors for Compact Sampling Calorimeters

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Abramowicz, H., Soto, M. Almanza, Benhammou, Y., Daniluk, W., Elad, M., Firlej, M., Fiutowski, T., Ghenescu, V., Grzelak, G., Horn, D., Huang, S., Idzik, M., Irles, A., Kotula, J., Levy, A., Levy, I., Lohmann, W., Morón, J., Neagu, A. T., Pietruch, D., Potlog, P. M., Świentek, K., Żarnecki, A. F., Zembaczyński, K.
Natura: Preprint
Pubblicazione: 2025
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866909649620434944
author Abramowicz, H.
Soto, M. Almanza
Benhammou, Y.
Daniluk, W.
Elad, M.
Firlej, M.
Fiutowski, T.
Ghenescu, V.
Grzelak, G.
Horn, D.
Huang, S.
Idzik, M.
Irles, A.
Kotula, J.
Levy, A.
Levy, I.
Lohmann, W.
Morón, J.
Neagu, A. T.
Pietruch, D.
Potlog, P. M.
Świentek, K.
Żarnecki, A. F.
Zembaczyński, K.
author_facet Abramowicz, H.
Soto, M. Almanza
Benhammou, Y.
Daniluk, W.
Elad, M.
Firlej, M.
Fiutowski, T.
Ghenescu, V.
Grzelak, G.
Horn, D.
Huang, S.
Idzik, M.
Irles, A.
Kotula, J.
Levy, A.
Levy, I.
Lohmann, W.
Morón, J.
Neagu, A. T.
Pietruch, D.
Potlog, P. M.
Świentek, K.
Żarnecki, A. F.
Zembaczyński, K.
contents Two samples of silicon pad sensors and two samples of GaAs sensors are studied in an electron beam with 5 GeV energy from the DESY-II test-beam facility. The sizes of the silicon and GaAs sensors are about 9$\times$9 cm$^2$ and 5$\times$8 cm$^2$, respectively. The thickness is 500 micrometer for both the silicon and GaAs sensors. The pad size is about 5$\times$5 mm$^2$. The sensors are foreseen to be used in a compact electromagnetic sampling calorimeter. The readout of the pads is done by metal traces connected to the pads and the front-end ASICs at the edges of the sensors. For the silicon sensors, copper traces on a Kapton foil are connected to the sensor pads with conducting glue. The pads of the GaAs sensors are connected to bond-pads via aluminium traces on the sensor substrate. The readout is based on a dedicated front-end ASIC, called FLAME. Pre-processing of the raw data and deconvolution is performed with FPGAs. The whole system is orchestrated by a Trigger Logic Unit. Results are shown for the signal-to-noise ratio, the homogeneity of the response, edge effects on pads, and for signals due to the readout traces.
format Preprint
id arxiv_https___arxiv_org_abs_2501_07431
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Novel Silicon and GaAs Sensors for Compact Sampling Calorimeters
Abramowicz, H.
Soto, M. Almanza
Benhammou, Y.
Daniluk, W.
Elad, M.
Firlej, M.
Fiutowski, T.
Ghenescu, V.
Grzelak, G.
Horn, D.
Huang, S.
Idzik, M.
Irles, A.
Kotula, J.
Levy, A.
Levy, I.
Lohmann, W.
Morón, J.
Neagu, A. T.
Pietruch, D.
Potlog, P. M.
Świentek, K.
Żarnecki, A. F.
Zembaczyński, K.
Instrumentation and Detectors
High Energy Physics - Experiment
Two samples of silicon pad sensors and two samples of GaAs sensors are studied in an electron beam with 5 GeV energy from the DESY-II test-beam facility. The sizes of the silicon and GaAs sensors are about 9$\times$9 cm$^2$ and 5$\times$8 cm$^2$, respectively. The thickness is 500 micrometer for both the silicon and GaAs sensors. The pad size is about 5$\times$5 mm$^2$. The sensors are foreseen to be used in a compact electromagnetic sampling calorimeter. The readout of the pads is done by metal traces connected to the pads and the front-end ASICs at the edges of the sensors. For the silicon sensors, copper traces on a Kapton foil are connected to the sensor pads with conducting glue. The pads of the GaAs sensors are connected to bond-pads via aluminium traces on the sensor substrate. The readout is based on a dedicated front-end ASIC, called FLAME. Pre-processing of the raw data and deconvolution is performed with FPGAs. The whole system is orchestrated by a Trigger Logic Unit. Results are shown for the signal-to-noise ratio, the homogeneity of the response, edge effects on pads, and for signals due to the readout traces.
title Novel Silicon and GaAs Sensors for Compact Sampling Calorimeters
topic Instrumentation and Detectors
High Energy Physics - Experiment
url https://arxiv.org/abs/2501.07431