Design and Performance of a Universal SiPM Readout System for X- and Gamma-Ray Missions

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Kole, Merlin, De Angelis, Nicolas, Produit, Nicolas, Azzarello, Philipp, Cadoux, Franck, Favre, Yannick, Greiner, Jochen, Kumar, Vishal, Hulsman, Johannes, Kusyk, Sebastian, Li, Hancheng, Rybka, Dominik, Stauffer, Jerome, Stil, Adrien, Sun, Jianchao, Swakon, Jan, Wrobel, Damian, Wu, Xin
Format: Preprint
Publié: 2025
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866908469798371328
author Kole, Merlin
De Angelis, Nicolas
Produit, Nicolas
Azzarello, Philipp
Cadoux, Franck
Favre, Yannick
Greiner, Jochen
Kumar, Vishal
Hulsman, Johannes
Kusyk, Sebastian
Li, Hancheng
Rybka, Dominik
Stauffer, Jerome
Stil, Adrien
Sun, Jianchao
Swakon, Jan
Wrobel, Damian
Wu, Xin
author_facet Kole, Merlin
De Angelis, Nicolas
Produit, Nicolas
Azzarello, Philipp
Cadoux, Franck
Favre, Yannick
Greiner, Jochen
Kumar, Vishal
Hulsman, Johannes
Kusyk, Sebastian
Li, Hancheng
Rybka, Dominik
Stauffer, Jerome
Stil, Adrien
Sun, Jianchao
Swakon, Jan
Wrobel, Damian
Wu, Xin
contents The advent of both multi-messenger and time-domain astrophysics over the last decade has seen a large interest in the development of small-scale, cheap, and robust gamma-ray detectors. This has been further encouraged by the availability of CubeSat platforms. Of particular interest are detectors capable of producing spectral and localization measurements of X and gamma-ray transients to allow for accurate follow-up measurements at different wavelengths. A vast number of the instruments developed for such purposes in the last years use a combination of scintillators and Silicon Photomultipliers (SiPMs) for photon detection. Here, we present the design, performance, and space qualification of a readout system capable of reading out 64 SiPM channels. This low-power and low-cost system was originally designed for the POLAR-2 mission, a large scale gamma-ray polarimeter. However, its flexible design makes it equally suitable for use on various CubeSat missions. The system was found to perform well when reading out both plastic and high Z scintillators using a total of 1.8~W. The space qualified design furthermore relies on commercial off-the-shelf components, thereby also removing most international export issues. In this paper, we will present the overall design, the performance of the electronics, its performance when reading out various scintillators and the successful space-qualification of this design.
format Preprint
id arxiv_https___arxiv_org_abs_2501_07758
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Design and Performance of a Universal SiPM Readout System for X- and Gamma-Ray Missions
Kole, Merlin
De Angelis, Nicolas
Produit, Nicolas
Azzarello, Philipp
Cadoux, Franck
Favre, Yannick
Greiner, Jochen
Kumar, Vishal
Hulsman, Johannes
Kusyk, Sebastian
Li, Hancheng
Rybka, Dominik
Stauffer, Jerome
Stil, Adrien
Sun, Jianchao
Swakon, Jan
Wrobel, Damian
Wu, Xin
Instrumentation and Methods for Astrophysics
The advent of both multi-messenger and time-domain astrophysics over the last decade has seen a large interest in the development of small-scale, cheap, and robust gamma-ray detectors. This has been further encouraged by the availability of CubeSat platforms. Of particular interest are detectors capable of producing spectral and localization measurements of X and gamma-ray transients to allow for accurate follow-up measurements at different wavelengths. A vast number of the instruments developed for such purposes in the last years use a combination of scintillators and Silicon Photomultipliers (SiPMs) for photon detection. Here, we present the design, performance, and space qualification of a readout system capable of reading out 64 SiPM channels. This low-power and low-cost system was originally designed for the POLAR-2 mission, a large scale gamma-ray polarimeter. However, its flexible design makes it equally suitable for use on various CubeSat missions. The system was found to perform well when reading out both plastic and high Z scintillators using a total of 1.8~W. The space qualified design furthermore relies on commercial off-the-shelf components, thereby also removing most international export issues. In this paper, we will present the overall design, the performance of the electronics, its performance when reading out various scintillators and the successful space-qualification of this design.
title Design and Performance of a Universal SiPM Readout System for X- and Gamma-Ray Missions
topic Instrumentation and Methods for Astrophysics
url https://arxiv.org/abs/2501.07758