In-situ high voltage generation with Cockcroft-Walton multiplier for xenon gas time projection chamber

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Akiyama, Shinichi, Hikida, Junya, Yoshida, Masashi, Nakamura, Kazuhiro, Ban, Sei, Hirose, Masanori, Ichikawa, Atsuko K., Iwashita, Yoshihisa, Kikawa, Tatsuya, Nakajima, Yasuhiro, Nakamura, Kiseki D., Nakaya, Tsuyoshi, Obara, Shuhei, Sakashita, Ken, Sekiya, Hiroyuki, Sugashima, Bungo, Urano, Soki, Hatsumi, Sota, Kobayashi, Sota, Sasaki, Hayato
Natura: Preprint
Pubblicazione: 2025
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866911659440734208
author Akiyama, Shinichi
Hikida, Junya
Yoshida, Masashi
Nakamura, Kazuhiro
Ban, Sei
Hirose, Masanori
Ichikawa, Atsuko K.
Iwashita, Yoshihisa
Kikawa, Tatsuya
Nakajima, Yasuhiro
Nakamura, Kiseki D.
Nakaya, Tsuyoshi
Obara, Shuhei
Sakashita, Ken
Sekiya, Hiroyuki
Sugashima, Bungo
Urano, Soki
Hatsumi, Sota
Kobayashi, Sota
Sasaki, Hayato
author_facet Akiyama, Shinichi
Hikida, Junya
Yoshida, Masashi
Nakamura, Kazuhiro
Ban, Sei
Hirose, Masanori
Ichikawa, Atsuko K.
Iwashita, Yoshihisa
Kikawa, Tatsuya
Nakajima, Yasuhiro
Nakamura, Kiseki D.
Nakaya, Tsuyoshi
Obara, Shuhei
Sakashita, Ken
Sekiya, Hiroyuki
Sugashima, Bungo
Urano, Soki
Hatsumi, Sota
Kobayashi, Sota
Sasaki, Hayato
contents We have newly developed a Cockcroft-Walton (CW) multiplier that can be used in a gas time projection chamber (TPC). A TPC requires a high voltage to form an electric field that drifts ionization electrons. Supplying the high voltage from outside the pressure vessel requires a dedicated high-voltage feedthrough. An alternative approach is to generate the high voltage inside the pressure vessel with a relatively low voltage introduced from outside. A CW multiplier can convert a low AC voltage input to a high DC voltage output, making it suitable for this purpose. We have integrated a CW multiplier into the AXEL (A Xenon ElectroLuminescence detector), a high pressure xenon gas TPC to search for neutrinoless double beta decay of $^{136}$Xe. It uses silicon photomultipliers to detect the ionization electrons through elecrtoluminescence, making it strong against electronic noise. Operation of the CW multiplier was successfully demonstrated; the TPC was operated for 40 days at 6.8 bar, and an energy resolution as high as (0.67 $\pm$ 0.08) % (FWHM) at 2615 keV was obtained.
format Preprint
id arxiv_https___arxiv_org_abs_2501_08554
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle In-situ high voltage generation with Cockcroft-Walton multiplier for xenon gas time projection chamber
Akiyama, Shinichi
Hikida, Junya
Yoshida, Masashi
Nakamura, Kazuhiro
Ban, Sei
Hirose, Masanori
Ichikawa, Atsuko K.
Iwashita, Yoshihisa
Kikawa, Tatsuya
Nakajima, Yasuhiro
Nakamura, Kiseki D.
Nakaya, Tsuyoshi
Obara, Shuhei
Sakashita, Ken
Sekiya, Hiroyuki
Sugashima, Bungo
Urano, Soki
Hatsumi, Sota
Kobayashi, Sota
Sasaki, Hayato
Instrumentation and Detectors
High Energy Physics - Experiment
Nuclear Experiment
We have newly developed a Cockcroft-Walton (CW) multiplier that can be used in a gas time projection chamber (TPC). A TPC requires a high voltage to form an electric field that drifts ionization electrons. Supplying the high voltage from outside the pressure vessel requires a dedicated high-voltage feedthrough. An alternative approach is to generate the high voltage inside the pressure vessel with a relatively low voltage introduced from outside. A CW multiplier can convert a low AC voltage input to a high DC voltage output, making it suitable for this purpose. We have integrated a CW multiplier into the AXEL (A Xenon ElectroLuminescence detector), a high pressure xenon gas TPC to search for neutrinoless double beta decay of $^{136}$Xe. It uses silicon photomultipliers to detect the ionization electrons through elecrtoluminescence, making it strong against electronic noise. Operation of the CW multiplier was successfully demonstrated; the TPC was operated for 40 days at 6.8 bar, and an energy resolution as high as (0.67 $\pm$ 0.08) % (FWHM) at 2615 keV was obtained.
title In-situ high voltage generation with Cockcroft-Walton multiplier for xenon gas time projection chamber
topic Instrumentation and Detectors
High Energy Physics - Experiment
Nuclear Experiment
url https://arxiv.org/abs/2501.08554