The Ultra-Low material budget GEM based TPC for tracking with VMM3a readout

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Garcia, F., Flöthner, K. J., Amato, A., Biswas, S., Brunbauer, F. M., Heiss, M. W., Janka, G., Janssens, D., Lisowska, M., Meurer, M., Muller, H., Oberhauser, B. Banto, Oliveri, E., Orlandini, G., Pfeiffer, D., Prokscha, T., Ropelewski, L., Scharenberg, L., Samarati, J., Sauli, F., van Stenis, M., Veenhof, R., Zeh, B., Zhao, X.
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866913744244703232
author Garcia, F.
Flöthner, K. J.
Amato, A.
Biswas, S.
Brunbauer, F. M.
Heiss, M. W.
Janka, G.
Janssens, D.
Lisowska, M.
Meurer, M.
Muller, H.
Oberhauser, B. Banto
Oliveri, E.
Orlandini, G.
Pfeiffer, D.
Prokscha, T.
Ropelewski, L.
Scharenberg, L.
Samarati, J.
Sauli, F.
van Stenis, M.
Veenhof, R.
Zeh, B.
Zhao, X.
author_facet Garcia, F.
Flöthner, K. J.
Amato, A.
Biswas, S.
Brunbauer, F. M.
Heiss, M. W.
Janka, G.
Janssens, D.
Lisowska, M.
Meurer, M.
Muller, H.
Oberhauser, B. Banto
Oliveri, E.
Orlandini, G.
Pfeiffer, D.
Prokscha, T.
Ropelewski, L.
Scharenberg, L.
Samarati, J.
Sauli, F.
van Stenis, M.
Veenhof, R.
Zeh, B.
Zhao, X.
contents The Gaseous Electron Multiplier-based Time Projection Chamber (GEM-TPC) in TWIN configuration for particle tracking has been consolidated after extensive investigations in different facilities to study its tracking performance. The most attractive feature of this detector is its ultra-low material budget, which is 0.28\% X/X$_0$ and can be further reduced by decreasing the thickness of the gas traversed by the incident particles. Thus, it provides excellent position reconstruction and reduced multi-scattering. This detector consists of two GEM-TPCs with drift fields in opposite directions, achieved by rotating one 180 degrees in the middle plane with respect to the other. These two GEM-TPCs share the same gas volume, i.e., inside a single vessel. This configuration is called a TWIN configuration. The results presented in this work were measured using the newly integrated VMM3a/SRS readout electronics, an important milestone in improving overall performance and capabilities. In 2024, this detector was tested at the H4 beamline of the SPS at CERN, using muons and pions and with different gas mixtures like, for instance: Ar/CO$_2$ (70/30 \%), He/CO$_2$ (70/30 \%) and He/CO$_2$ (90/10 \%). The helium-based mixtures were used to commission the detector to track low momenta muons required in the PSI muon-induced X-ray emission (MIXE) experiment. The results obtained from these measurements, a brief discussion of the methodology used for the data analysis, and a comparison of the spatial resolution for different gas mixtures will be presented.
format Preprint
id arxiv_https___arxiv_org_abs_2501_09587
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle The Ultra-Low material budget GEM based TPC for tracking with VMM3a readout
Garcia, F.
Flöthner, K. J.
Amato, A.
Biswas, S.
Brunbauer, F. M.
Heiss, M. W.
Janka, G.
Janssens, D.
Lisowska, M.
Meurer, M.
Muller, H.
Oberhauser, B. Banto
Oliveri, E.
Orlandini, G.
Pfeiffer, D.
Prokscha, T.
Ropelewski, L.
Scharenberg, L.
Samarati, J.
Sauli, F.
van Stenis, M.
Veenhof, R.
Zeh, B.
Zhao, X.
Instrumentation and Detectors
High Energy Physics - Experiment
The Gaseous Electron Multiplier-based Time Projection Chamber (GEM-TPC) in TWIN configuration for particle tracking has been consolidated after extensive investigations in different facilities to study its tracking performance. The most attractive feature of this detector is its ultra-low material budget, which is 0.28\% X/X$_0$ and can be further reduced by decreasing the thickness of the gas traversed by the incident particles. Thus, it provides excellent position reconstruction and reduced multi-scattering. This detector consists of two GEM-TPCs with drift fields in opposite directions, achieved by rotating one 180 degrees in the middle plane with respect to the other. These two GEM-TPCs share the same gas volume, i.e., inside a single vessel. This configuration is called a TWIN configuration. The results presented in this work were measured using the newly integrated VMM3a/SRS readout electronics, an important milestone in improving overall performance and capabilities. In 2024, this detector was tested at the H4 beamline of the SPS at CERN, using muons and pions and with different gas mixtures like, for instance: Ar/CO$_2$ (70/30 \%), He/CO$_2$ (70/30 \%) and He/CO$_2$ (90/10 \%). The helium-based mixtures were used to commission the detector to track low momenta muons required in the PSI muon-induced X-ray emission (MIXE) experiment. The results obtained from these measurements, a brief discussion of the methodology used for the data analysis, and a comparison of the spatial resolution for different gas mixtures will be presented.
title The Ultra-Low material budget GEM based TPC for tracking with VMM3a readout
topic Instrumentation and Detectors
High Energy Physics - Experiment
url https://arxiv.org/abs/2501.09587