Upgrades and maintenance of the CRYRING@ESR electron cooler for improved internal electron target operation

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Koutsostathis, Athanasios, Krantz, Claude, Hanu, Elena-Oana, Herfurth, Frank, Heß, Regina, Kaufmann, Wolfgang, Lestinsky, Michael, Looshorn, Mirko Dieter, Menz, Esther Babette, Reiter, Andreas, Roßbach, Jon, Schippers, Stefan, Suherman, Phe Man
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866909712542334976
author Koutsostathis, Athanasios
Krantz, Claude
Hanu, Elena-Oana
Herfurth, Frank
Heß, Regina
Kaufmann, Wolfgang
Lestinsky, Michael
Looshorn, Mirko Dieter
Menz, Esther Babette
Reiter, Andreas
Roßbach, Jon
Schippers, Stefan
Suherman, Phe Man
author_facet Koutsostathis, Athanasios
Krantz, Claude
Hanu, Elena-Oana
Herfurth, Frank
Heß, Regina
Kaufmann, Wolfgang
Lestinsky, Michael
Looshorn, Mirko Dieter
Menz, Esther Babette
Reiter, Andreas
Roßbach, Jon
Schippers, Stefan
Suherman, Phe Man
contents The electron cooler of the CRYRING@ESR storage ring at the GSI-FAIR accelerator complex is a unique instrument, which not only provides beam cooling of the stored ions, but also serves as a low-energy electron target for Dielectronic Recombination experiments. The minimisation of vacuum contamination and the response to rapid energy changes are key requirements of the cooler in electron target mode. Therefore, a test bench was prepared to study the outgassing behaviour of the electron gun components and a setup was constructed to evaluate the drift-electrode-modulation of the acceleration voltage of the cooler. The vacuum studies showed that the electron gun cathode was severely malfunctioning and resulted in its replacement. The drift-electrode-modulation of the acceleration voltage showed significant improvements compared to direct modulation of the terminal voltage of the cooler.
format Preprint
id arxiv_https___arxiv_org_abs_2501_14690
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Upgrades and maintenance of the CRYRING@ESR electron cooler for improved internal electron target operation
Koutsostathis, Athanasios
Krantz, Claude
Hanu, Elena-Oana
Herfurth, Frank
Heß, Regina
Kaufmann, Wolfgang
Lestinsky, Michael
Looshorn, Mirko Dieter
Menz, Esther Babette
Reiter, Andreas
Roßbach, Jon
Schippers, Stefan
Suherman, Phe Man
Accelerator Physics
Nuclear Experiment
Atomic Physics
Instrumentation and Detectors
The electron cooler of the CRYRING@ESR storage ring at the GSI-FAIR accelerator complex is a unique instrument, which not only provides beam cooling of the stored ions, but also serves as a low-energy electron target for Dielectronic Recombination experiments. The minimisation of vacuum contamination and the response to rapid energy changes are key requirements of the cooler in electron target mode. Therefore, a test bench was prepared to study the outgassing behaviour of the electron gun components and a setup was constructed to evaluate the drift-electrode-modulation of the acceleration voltage of the cooler. The vacuum studies showed that the electron gun cathode was severely malfunctioning and resulted in its replacement. The drift-electrode-modulation of the acceleration voltage showed significant improvements compared to direct modulation of the terminal voltage of the cooler.
title Upgrades and maintenance of the CRYRING@ESR electron cooler for improved internal electron target operation
topic Accelerator Physics
Nuclear Experiment
Atomic Physics
Instrumentation and Detectors
url https://arxiv.org/abs/2501.14690