On the resolution of dual readout calorimeters

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Eno, S., Wu, L., Aamir, M. Y., Chekanov, S. V., Nabili, S., Palmer, C.
Format: Preprint
Veröffentlicht: 2025
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866910804359512064
author Eno, S.
Wu, L.
Aamir, M. Y.
Chekanov, S. V.
Nabili, S.
Palmer, C.
author_facet Eno, S.
Wu, L.
Aamir, M. Y.
Chekanov, S. V.
Nabili, S.
Palmer, C.
contents Dual readout calorimeters allow state-of-the-art resolutions for hadronic energy measurements. Their various incarnations are leading candidates for the calorimeter systems for future colliders. In this paper, we present a simple formula for the resolution of a dual readout calorimeter, which we verify with a toy simulation and with full simulation results. This formula can help those new to dual readout calorimetry understand its strengths and limitations. The paper also highlights that the dual readout correction works not just to compensate for binding energy loss, but also for energies escaping the calorimeter or clustering algorithm. Formulae are also presented for approximate resolutions and energy scales in terms of different sources of response.
format Preprint
id arxiv_https___arxiv_org_abs_2501_15329
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle On the resolution of dual readout calorimeters
Eno, S.
Wu, L.
Aamir, M. Y.
Chekanov, S. V.
Nabili, S.
Palmer, C.
Instrumentation and Detectors
High Energy Physics - Experiment
Dual readout calorimeters allow state-of-the-art resolutions for hadronic energy measurements. Their various incarnations are leading candidates for the calorimeter systems for future colliders. In this paper, we present a simple formula for the resolution of a dual readout calorimeter, which we verify with a toy simulation and with full simulation results. This formula can help those new to dual readout calorimetry understand its strengths and limitations. The paper also highlights that the dual readout correction works not just to compensate for binding energy loss, but also for energies escaping the calorimeter or clustering algorithm. Formulae are also presented for approximate resolutions and energy scales in terms of different sources of response.
title On the resolution of dual readout calorimeters
topic Instrumentation and Detectors
High Energy Physics - Experiment
url https://arxiv.org/abs/2501.15329