A Study of Afterglow Signatures in NaI and CsI Scintillator Modules for the Background and Transient Observer Instrument on COSI

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Gulick, Hannah, Yoneda, Hiroki, Takahashi, Tadayuki, Chen, Claire, Nakazawa, Kazuhiro, Nagasawa, Shunsaku, Ando, Mii, Okuma, Keigo, Joens, Alyson, Nussirat, Samer Al, Shimizu, Yasuyuki, Fujisawa, Kaito, Kohmura, Takayoshi, Hagino, Kouichi, Kitamura, Hisashi, Zoglauer, Andreas, Oliveros, Juan Carlos Martinez, Tomsick, John A.
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866929689003556864
author Gulick, Hannah
Yoneda, Hiroki
Takahashi, Tadayuki
Chen, Claire
Nakazawa, Kazuhiro
Nagasawa, Shunsaku
Ando, Mii
Okuma, Keigo
Joens, Alyson
Nussirat, Samer Al
Shimizu, Yasuyuki
Fujisawa, Kaito
Kohmura, Takayoshi
Hagino, Kouichi
Kitamura, Hisashi
Zoglauer, Andreas
Oliveros, Juan Carlos Martinez
Tomsick, John A.
author_facet Gulick, Hannah
Yoneda, Hiroki
Takahashi, Tadayuki
Chen, Claire
Nakazawa, Kazuhiro
Nagasawa, Shunsaku
Ando, Mii
Okuma, Keigo
Joens, Alyson
Nussirat, Samer Al
Shimizu, Yasuyuki
Fujisawa, Kaito
Kohmura, Takayoshi
Hagino, Kouichi
Kitamura, Hisashi
Zoglauer, Andreas
Oliveros, Juan Carlos Martinez
Tomsick, John A.
contents We present measurements of the afterglow signatures in NaI(Tl) and CsI(Tl) detector modules as part of the Background and Transient Observer (BTO) mission detector trade-study. BTO is a NASA Student Collaboration Project flying on the Compton Spectrometer and Imager (COSI) Small Explorer mission in 2027. The detectors utilized in this study are cylindrical in shape with a height and diameter of 5.1 cm and were read out by silicon photomultipliers (SiPMs). We conducted a radiation campaign at the HIMAC accelerator in Japan where the scintillators were irradiated with a 230 MeV/u helium beam (He beam) and 350 MeV/u carbon beam (C beam). We find that both the CsI and NaI scintillators exhibit afterglow signatures when irradiated with the C and He beams. The CsI crystal exhibits a stronger afterglow intensity with afterglow pulses occurring for an average 2.40 ms for C and 0.9 ms for He after the initial particle pulse. The duration of afterglow pulses in CsI is 8.6x and 5.6x the afterglow signal duration in NaI for C and He (0.28 ms and 0.16 ms, respectively). Although CsI has advantages such as a higher light yield and radiation hardness, the stronger afterglows in the CsI detector increase the complexity of the electronics and lead to a ~7x larger dead time per afterglow event or a ~3x higher energy threshold value. We use the measured dead times to predict the amount of observing time lost to afterglow-inducing events for an instrument like BTO in low Earth orbit. We simulate the background rates in a BTO-like orbit and find a total value of 114 counts/s for the full two-detector system. Based on the particle energies in the HIMAC experiment, we then determine that an event with sufficient energy to produce an afterglow signal occurs once every ~70 s and ~1.4 s in NaI and CsI detectors, respectively. Thus, we conclude that NaI is the better choice for the BTO mission.
format Preprint
id arxiv_https___arxiv_org_abs_2501_16434
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle A Study of Afterglow Signatures in NaI and CsI Scintillator Modules for the Background and Transient Observer Instrument on COSI
Gulick, Hannah
Yoneda, Hiroki
Takahashi, Tadayuki
Chen, Claire
Nakazawa, Kazuhiro
Nagasawa, Shunsaku
Ando, Mii
Okuma, Keigo
Joens, Alyson
Nussirat, Samer Al
Shimizu, Yasuyuki
Fujisawa, Kaito
Kohmura, Takayoshi
Hagino, Kouichi
Kitamura, Hisashi
Zoglauer, Andreas
Oliveros, Juan Carlos Martinez
Tomsick, John A.
Instrumentation and Methods for Astrophysics
Instrumentation and Detectors
We present measurements of the afterglow signatures in NaI(Tl) and CsI(Tl) detector modules as part of the Background and Transient Observer (BTO) mission detector trade-study. BTO is a NASA Student Collaboration Project flying on the Compton Spectrometer and Imager (COSI) Small Explorer mission in 2027. The detectors utilized in this study are cylindrical in shape with a height and diameter of 5.1 cm and were read out by silicon photomultipliers (SiPMs). We conducted a radiation campaign at the HIMAC accelerator in Japan where the scintillators were irradiated with a 230 MeV/u helium beam (He beam) and 350 MeV/u carbon beam (C beam). We find that both the CsI and NaI scintillators exhibit afterglow signatures when irradiated with the C and He beams. The CsI crystal exhibits a stronger afterglow intensity with afterglow pulses occurring for an average 2.40 ms for C and 0.9 ms for He after the initial particle pulse. The duration of afterglow pulses in CsI is 8.6x and 5.6x the afterglow signal duration in NaI for C and He (0.28 ms and 0.16 ms, respectively). Although CsI has advantages such as a higher light yield and radiation hardness, the stronger afterglows in the CsI detector increase the complexity of the electronics and lead to a ~7x larger dead time per afterglow event or a ~3x higher energy threshold value. We use the measured dead times to predict the amount of observing time lost to afterglow-inducing events for an instrument like BTO in low Earth orbit. We simulate the background rates in a BTO-like orbit and find a total value of 114 counts/s for the full two-detector system. Based on the particle energies in the HIMAC experiment, we then determine that an event with sufficient energy to produce an afterglow signal occurs once every ~70 s and ~1.4 s in NaI and CsI detectors, respectively. Thus, we conclude that NaI is the better choice for the BTO mission.
title A Study of Afterglow Signatures in NaI and CsI Scintillator Modules for the Background and Transient Observer Instrument on COSI
topic Instrumentation and Methods for Astrophysics
Instrumentation and Detectors
url https://arxiv.org/abs/2501.16434