contents The presence of critical resonances in microwave power amplifiers has a negative impact on its behavior and performance. These critical resonances are usually predicted from pole-zero stability simulations. In this paper, a different and less demanding approach for the circuit designer is proposed. It is based on performing noise simulations of the amplifier and observing the rise in the noise spectrum that happens when the system has low damping poles. Critical resonance detection is simplified since no additional probes have to be inserted in the circuit and no post-processing for pole-zero analysis is required. The technique is applied to two amplifier prototypes fabricated in microstrip hybrid technology and the results are compared with the conventional pole-zero approach.
format Preprint
id arxiv_https___arxiv_org_abs_2501_16928
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Detecting Critical Resonances in Microwave Amplifiers through Noise Simulations
Collantes, Juan-Mari
Otegi, Nerea
Anakabe, Aitziber
Mori, Libe
Barcenilla, Asier
Gonzalez-Perez, Jose Manuel
Instrumentation and Detectors
Systems and Control
The presence of critical resonances in microwave power amplifiers has a negative impact on its behavior and performance. These critical resonances are usually predicted from pole-zero stability simulations. In this paper, a different and less demanding approach for the circuit designer is proposed. It is based on performing noise simulations of the amplifier and observing the rise in the noise spectrum that happens when the system has low damping poles. Critical resonance detection is simplified since no additional probes have to be inserted in the circuit and no post-processing for pole-zero analysis is required. The technique is applied to two amplifier prototypes fabricated in microstrip hybrid technology and the results are compared with the conventional pole-zero approach.
title Detecting Critical Resonances in Microwave Amplifiers through Noise Simulations
topic Instrumentation and Detectors
Systems and Control
url https://arxiv.org/abs/2501.16928