On Overlap Ratio in Defocused Electron Ptychography

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Moshtaghpour, Amirafshar, Kirkland, Angus I.
Formato: Preprint
Publicado: 2025
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866916736548208640
author Moshtaghpour, Amirafshar
Kirkland, Angus I.
author_facet Moshtaghpour, Amirafshar
Kirkland, Angus I.
contents Four-dimensional Scanning Transmission Electron Microscopy (4D STEM) with data acquired using a defocused electron probe is a promising tool for characterising complex biological specimens and materials through a phase retrieval process known as Electron Ptychography (EP). The efficacy of 4D STEM acquisition and the resulting quality of EP reconstruction depends on the overlap ratio of adjacent illuminated areas. This paper demonstrates how the overlap ratio impacts the data redundancy and the quality of the EP reconstruction. We define two quantities as a function of the overlap ratio that are independent of both the object and the EP algorithm. Subsequently, we evaluate an EP algorithm for varying overlap ratios using simulated 4D STEM datasets. Notably, a 40% or greater overlap ratio yields stable, high-quality reconstructions.
format Preprint
id arxiv_https___arxiv_org_abs_2502_00762
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle On Overlap Ratio in Defocused Electron Ptychography
Moshtaghpour, Amirafshar
Kirkland, Angus I.
Signal Processing
Information Retrieval
Applied Physics
Medical Physics
Four-dimensional Scanning Transmission Electron Microscopy (4D STEM) with data acquired using a defocused electron probe is a promising tool for characterising complex biological specimens and materials through a phase retrieval process known as Electron Ptychography (EP). The efficacy of 4D STEM acquisition and the resulting quality of EP reconstruction depends on the overlap ratio of adjacent illuminated areas. This paper demonstrates how the overlap ratio impacts the data redundancy and the quality of the EP reconstruction. We define two quantities as a function of the overlap ratio that are independent of both the object and the EP algorithm. Subsequently, we evaluate an EP algorithm for varying overlap ratios using simulated 4D STEM datasets. Notably, a 40% or greater overlap ratio yields stable, high-quality reconstructions.
title On Overlap Ratio in Defocused Electron Ptychography
topic Signal Processing
Information Retrieval
Applied Physics
Medical Physics
url https://arxiv.org/abs/2502.00762