Explainable and externally validated machine learning for neurocognitive diagnosis via electrocardiograms

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Alcaraz, Juan Miguel Lopez, Oloyede, Ebenezer, Taylor, David, Haverkamp, Wilhelm, Strodthoff, Nils
Format: Preprint
Publié: 2025
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866909912617975808
author Alcaraz, Juan Miguel Lopez
Oloyede, Ebenezer
Taylor, David
Haverkamp, Wilhelm
Strodthoff, Nils
author_facet Alcaraz, Juan Miguel Lopez
Oloyede, Ebenezer
Taylor, David
Haverkamp, Wilhelm
Strodthoff, Nils
contents Background: Electrocardiogram (ECG) analysis has emerged as a promising tool for detecting physiological changes linked to non-cardiac disorders. Given the close connection between cardiovascular and neurocognitive health, ECG abnormalities may be present in individuals with co-occurring neurocognitive conditions. This highlights the potential of ECG as a biomarker to improve detection, therapy monitoring, and risk stratification in patients with neurocognitive disorders, an area that remains underexplored. Methods: We aim to demonstrate the feasibility to predict neurocognitive disorders from ECG features across diverse patient populations. We utilized ECG features and demographic data to predict neurocognitive disorders defined by ICD-10 codes, focusing on dementia, delirium, and Parkinson's disease. Internal and external validations were performed using the MIMIC-IV and ECG-View datasets. Predictive performance was assessed using AUROC scores, and Shapley values were used to interpret feature contributions. Results: Significant predictive performance was observed for disorders within the neurcognitive disorders. Significantly, the disorders with the highest predictive performance is F03: Dementia, with an internal AUROC of 0.848 (95% CI: 0.848-0.848) and an external AUROC of 0.865 (0.864-0.965), followed by G30: Alzheimer's, with an internal AUROC of 0.809 (95% CI: 0.808-0.810) and an external AUROC of 0.863 (95% CI: 0.863-0.864). Feature importance analysis revealed both known and novel ECG correlates. ECGs hold promise as non-invasive, explainable biomarkers for selected neurocognitive disorders. This study demonstrates robust performance across cohorts and lays the groundwork for future clinical applications, including early detection and personalized monitoring.
format Preprint
id arxiv_https___arxiv_org_abs_2502_04918
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Explainable and externally validated machine learning for neurocognitive diagnosis via electrocardiograms
Alcaraz, Juan Miguel Lopez
Oloyede, Ebenezer
Taylor, David
Haverkamp, Wilhelm
Strodthoff, Nils
Signal Processing
Machine Learning
Background: Electrocardiogram (ECG) analysis has emerged as a promising tool for detecting physiological changes linked to non-cardiac disorders. Given the close connection between cardiovascular and neurocognitive health, ECG abnormalities may be present in individuals with co-occurring neurocognitive conditions. This highlights the potential of ECG as a biomarker to improve detection, therapy monitoring, and risk stratification in patients with neurocognitive disorders, an area that remains underexplored. Methods: We aim to demonstrate the feasibility to predict neurocognitive disorders from ECG features across diverse patient populations. We utilized ECG features and demographic data to predict neurocognitive disorders defined by ICD-10 codes, focusing on dementia, delirium, and Parkinson's disease. Internal and external validations were performed using the MIMIC-IV and ECG-View datasets. Predictive performance was assessed using AUROC scores, and Shapley values were used to interpret feature contributions. Results: Significant predictive performance was observed for disorders within the neurcognitive disorders. Significantly, the disorders with the highest predictive performance is F03: Dementia, with an internal AUROC of 0.848 (95% CI: 0.848-0.848) and an external AUROC of 0.865 (0.864-0.965), followed by G30: Alzheimer's, with an internal AUROC of 0.809 (95% CI: 0.808-0.810) and an external AUROC of 0.863 (95% CI: 0.863-0.864). Feature importance analysis revealed both known and novel ECG correlates. ECGs hold promise as non-invasive, explainable biomarkers for selected neurocognitive disorders. This study demonstrates robust performance across cohorts and lays the groundwork for future clinical applications, including early detection and personalized monitoring.
title Explainable and externally validated machine learning for neurocognitive diagnosis via electrocardiograms
topic Signal Processing
Machine Learning
url https://arxiv.org/abs/2502.04918