Scattered light reduction in Sagnac Speed Meters with Tunable Coherence

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Eggers, Leonie, Voigt, Daniel, Gerberding, Oliver
Format: Preprint
Veröffentlicht: 2025
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866915893798240256
author Eggers, Leonie
Voigt, Daniel
Gerberding, Oliver
author_facet Eggers, Leonie
Voigt, Daniel
Gerberding, Oliver
contents Sagnac Speed Meter and ring resonators can be used as high precision instruments, but they are limited in their sensitivity through scattered light causing non-linear noise. Here, we experimentally demonstrate a technique called Tunable Coherence, where the long coherence length of the laser is broken in a controlled way, to suppress the coupling of scattered light in a Sagnac interferometer. We demonstrate a scattered light suppression of 24.2 dB in a Sagnac interferometer and discuss the experimental limitations. Further, we show an analytical discussion on how Tunable Coherence could be a fundamental solution to light scattering back from optical surfaces into the counter propagating beam, which is an issue particularly in ring resonators.
format Preprint
id arxiv_https___arxiv_org_abs_2502_07383
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Scattered light reduction in Sagnac Speed Meters with Tunable Coherence
Eggers, Leonie
Voigt, Daniel
Gerberding, Oliver
Optics
Instrumentation and Methods for Astrophysics
General Relativity and Quantum Cosmology
Instrumentation and Detectors
Sagnac Speed Meter and ring resonators can be used as high precision instruments, but they are limited in their sensitivity through scattered light causing non-linear noise. Here, we experimentally demonstrate a technique called Tunable Coherence, where the long coherence length of the laser is broken in a controlled way, to suppress the coupling of scattered light in a Sagnac interferometer. We demonstrate a scattered light suppression of 24.2 dB in a Sagnac interferometer and discuss the experimental limitations. Further, we show an analytical discussion on how Tunable Coherence could be a fundamental solution to light scattering back from optical surfaces into the counter propagating beam, which is an issue particularly in ring resonators.
title Scattered light reduction in Sagnac Speed Meters with Tunable Coherence
topic Optics
Instrumentation and Methods for Astrophysics
General Relativity and Quantum Cosmology
Instrumentation and Detectors
url https://arxiv.org/abs/2502.07383