Towards personalised assessment of abdominal aortic aneurysm structural integrity

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Jamshidian, Mostafa, Wittek, Adam, Sekhavat, Saeideh, Mufty, Hozan, Maleux, Geert, Fourneau, Inge, Gizewski, Elke R., Gassner, Eva, Loizides, Alexander, Lutz, Maximilian, Enzmann, Florian K., Liepvre, Donatien Le, Bernard, Florian, Minvielle, Ludovic, Fondanèche, Antoine, Miller, Karol
Format: Preprint
Publié: 2025
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866910017028882432
author Jamshidian, Mostafa
Wittek, Adam
Sekhavat, Saeideh
Mufty, Hozan
Maleux, Geert
Fourneau, Inge
Gizewski, Elke R.
Gassner, Eva
Loizides, Alexander
Lutz, Maximilian
Enzmann, Florian K.
Liepvre, Donatien Le
Bernard, Florian
Minvielle, Ludovic
Fondanèche, Antoine
Miller, Karol
author_facet Jamshidian, Mostafa
Wittek, Adam
Sekhavat, Saeideh
Mufty, Hozan
Maleux, Geert
Fourneau, Inge
Gizewski, Elke R.
Gassner, Eva
Loizides, Alexander
Lutz, Maximilian
Enzmann, Florian K.
Liepvre, Donatien Le
Bernard, Florian
Minvielle, Ludovic
Fondanèche, Antoine
Miller, Karol
contents Abdominal aortic aneurysm (AAA) is a life-threatening condition characterized by the progressive dilation of the aorta, which can lead to rupture if undetected or untreated. Stress-based rupture risk estimation using computational biomechanics has been widely studied; however, it requires wall strength data that cannot be measured in humans in vivo. To overcome this limitation, the goal of this study is to present a new method for biomechanical assessment of AAA via simultaneous consideration of tension and strain in AAA wall. We present a patient-specific, non-invasive method for assessing the structural integrity of the AAA wall using only time-resolved 3D computed tomography angiography (4D-CTA) images and blood pressure data. The proposed approach integrates wall strain (throughout the cardiac cycle) and wall tension analysis to compute a novel index, the Relative Structural Integrity Index (RSII), which quantifies local wall stiffness independently of wall thickness, wall material properties, and blood pressure measurement conditions. We applied our method to twenty patients from three different hospitals to extract visual RSII maps over the AAA wall of each individual patient and to compare the RSII values between aneurysmal and non-aneurysmal aortas in one patient. Our results primarily show similar RSII values across all patients, indicating the consistency of the method. Additionally, we observed patterns consistent with experimental findings reported in the literature: AAA walls exhibited higher stiffness than healthy aortic walls, while localized low-stiffness zones in the AAA wall were predominantly found in the most dilated regions.
format Preprint
id arxiv_https___arxiv_org_abs_2502_09905
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Towards personalised assessment of abdominal aortic aneurysm structural integrity
Jamshidian, Mostafa
Wittek, Adam
Sekhavat, Saeideh
Mufty, Hozan
Maleux, Geert
Fourneau, Inge
Gizewski, Elke R.
Gassner, Eva
Loizides, Alexander
Lutz, Maximilian
Enzmann, Florian K.
Liepvre, Donatien Le
Bernard, Florian
Minvielle, Ludovic
Fondanèche, Antoine
Miller, Karol
Computational Engineering, Finance, and Science
Abdominal aortic aneurysm (AAA) is a life-threatening condition characterized by the progressive dilation of the aorta, which can lead to rupture if undetected or untreated. Stress-based rupture risk estimation using computational biomechanics has been widely studied; however, it requires wall strength data that cannot be measured in humans in vivo. To overcome this limitation, the goal of this study is to present a new method for biomechanical assessment of AAA via simultaneous consideration of tension and strain in AAA wall. We present a patient-specific, non-invasive method for assessing the structural integrity of the AAA wall using only time-resolved 3D computed tomography angiography (4D-CTA) images and blood pressure data. The proposed approach integrates wall strain (throughout the cardiac cycle) and wall tension analysis to compute a novel index, the Relative Structural Integrity Index (RSII), which quantifies local wall stiffness independently of wall thickness, wall material properties, and blood pressure measurement conditions. We applied our method to twenty patients from three different hospitals to extract visual RSII maps over the AAA wall of each individual patient and to compare the RSII values between aneurysmal and non-aneurysmal aortas in one patient. Our results primarily show similar RSII values across all patients, indicating the consistency of the method. Additionally, we observed patterns consistent with experimental findings reported in the literature: AAA walls exhibited higher stiffness than healthy aortic walls, while localized low-stiffness zones in the AAA wall were predominantly found in the most dilated regions.
title Towards personalised assessment of abdominal aortic aneurysm structural integrity
topic Computational Engineering, Finance, and Science
url https://arxiv.org/abs/2502.09905