Readout Optimization of Multi-Amplifier Sensing Charge-Coupled Devices for Single-Quantum Measurement

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Botti, Ana M., Cervantes-Vergara, Brenda A., Chavez, Claudio R., Chierchie, Fernando, Drlica-Wagner, Alex, Estrada, Juan, Moroni, Guillermo Fernandez, Holland, Stephen E., Gimenez, Blas J. Irigoyen, Lapi, Agustin J., Villalpando, Edgar Marrufo, Haro, Miguel Sofo, Tiffenberg, Javier, Uemura, Sho, Lin, Kenneth, Karcher, Armin, Guy, Julien, Nugent, Peter E.
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866910840165236736
author Botti, Ana M.
Cervantes-Vergara, Brenda A.
Chavez, Claudio R.
Chierchie, Fernando
Drlica-Wagner, Alex
Estrada, Juan
Moroni, Guillermo Fernandez
Holland, Stephen E.
Gimenez, Blas J. Irigoyen
Lapi, Agustin J.
Villalpando, Edgar Marrufo
Haro, Miguel Sofo
Tiffenberg, Javier
Uemura, Sho
Lin, Kenneth
Karcher, Armin
Guy, Julien
Nugent, Peter E.
author_facet Botti, Ana M.
Cervantes-Vergara, Brenda A.
Chavez, Claudio R.
Chierchie, Fernando
Drlica-Wagner, Alex
Estrada, Juan
Moroni, Guillermo Fernandez
Holland, Stephen E.
Gimenez, Blas J. Irigoyen
Lapi, Agustin J.
Villalpando, Edgar Marrufo
Haro, Miguel Sofo
Tiffenberg, Javier
Uemura, Sho
Lin, Kenneth
Karcher, Armin
Guy, Julien
Nugent, Peter E.
contents The non-destructive readout capability of the Skipper Charge Coupled Device (CCD) has been demonstrated to reduce the noise limitation of conventional silicon devices to levels that allow single-photon or single-electron counting. The noise reduction is achieved by taking multiple measurements of the charge in each pixel. These multiple measurements come at the cost of extra readout time, which has been a limitation for the broader adoption of this technology in particle physics, quantum imaging, and astronomy applications. This work presents recent results of a novel sensor architecture that uses multiple non-destructive floating-gate amplifiers in series to achieve sub-electron readout noise in a thick, fully-depleted silicon detector to overcome the readout time overhead of the Skipper-CCD. This sensor is called the Multiple-Amplifier Sensing Charge-Coupled Device (MAS-CCD) can perform multiple independent charge measurements with each amplifier, and the measurements from multiple amplifiers can be combined to further reduce the readout noise. We will show results obtained for sensors with 8 and 16 amplifiers per readout stage in new readout operations modes to optimize its readout speed. The noise reduction capability of the new techniques will be demonstrated in terms of its ability to reduce the noise by combining the information from the different amplifiers, and to resolve signals in the order of a single photon per pixel. The first readout operation explored here avoids the extra readout time needed in the MAS-CCD to read a line of the sensor associated with the extra extent of the serial register. The second technique explore the capability of the MAS-CCD device to perform a region of interest readout increasing the number of multiple samples per amplifier in a targeted region of the active area of the device.
format Preprint
id arxiv_https___arxiv_org_abs_2502_10508
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Readout Optimization of Multi-Amplifier Sensing Charge-Coupled Devices for Single-Quantum Measurement
Botti, Ana M.
Cervantes-Vergara, Brenda A.
Chavez, Claudio R.
Chierchie, Fernando
Drlica-Wagner, Alex
Estrada, Juan
Moroni, Guillermo Fernandez
Holland, Stephen E.
Gimenez, Blas J. Irigoyen
Lapi, Agustin J.
Villalpando, Edgar Marrufo
Haro, Miguel Sofo
Tiffenberg, Javier
Uemura, Sho
Lin, Kenneth
Karcher, Armin
Guy, Julien
Nugent, Peter E.
Instrumentation and Methods for Astrophysics
Instrumentation and Detectors
The non-destructive readout capability of the Skipper Charge Coupled Device (CCD) has been demonstrated to reduce the noise limitation of conventional silicon devices to levels that allow single-photon or single-electron counting. The noise reduction is achieved by taking multiple measurements of the charge in each pixel. These multiple measurements come at the cost of extra readout time, which has been a limitation for the broader adoption of this technology in particle physics, quantum imaging, and astronomy applications. This work presents recent results of a novel sensor architecture that uses multiple non-destructive floating-gate amplifiers in series to achieve sub-electron readout noise in a thick, fully-depleted silicon detector to overcome the readout time overhead of the Skipper-CCD. This sensor is called the Multiple-Amplifier Sensing Charge-Coupled Device (MAS-CCD) can perform multiple independent charge measurements with each amplifier, and the measurements from multiple amplifiers can be combined to further reduce the readout noise. We will show results obtained for sensors with 8 and 16 amplifiers per readout stage in new readout operations modes to optimize its readout speed. The noise reduction capability of the new techniques will be demonstrated in terms of its ability to reduce the noise by combining the information from the different amplifiers, and to resolve signals in the order of a single photon per pixel. The first readout operation explored here avoids the extra readout time needed in the MAS-CCD to read a line of the sensor associated with the extra extent of the serial register. The second technique explore the capability of the MAS-CCD device to perform a region of interest readout increasing the number of multiple samples per amplifier in a targeted region of the active area of the device.
title Readout Optimization of Multi-Amplifier Sensing Charge-Coupled Devices for Single-Quantum Measurement
topic Instrumentation and Methods for Astrophysics
Instrumentation and Detectors
url https://arxiv.org/abs/2502.10508