Triaxial Alignment Magnetometer Utilizing Free-Spin Precession in the Geomagnetic Range

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Jin, Ge, Shi, Tao, Zou, Sheng
Natura: Preprint
Pubblicazione: 2025
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866916617844162560
author Jin, Ge
Shi, Tao
Zou, Sheng
author_facet Jin, Ge
Shi, Tao
Zou, Sheng
contents In this paper, we present a triaxial alignment magnetometer based on free-spin precession deployed in the geomagnetic range. Existing vector measurement methods often require complex optical setups, heating structures, and laser modulation. This study addresses this challenge by employing a linearly polarized probe beam to induce atomic alignment and subsequently detecting the optical polarization rotation caused by the pulsed radio frequency field. The experiment is conducted in a paraffin-coated cell without buffer gas at room temperature, containing rubidium with natural abundance. We report triaxial measurements with a static magnetic field amplitude of approximately 50 $μ{\text{T}}$ (close to Earth's magnetic field), where the noise levels for each axis are approximately 5.3 ${\text{pT/}}\sqrt{\text{Hz}}$, 4.7 ${\text{pT/}}\sqrt{\text{Hz}}$, and 9.3 ${\text{pT/}}\sqrt{\text{Hz}}$ respectively. The proposed method demonstrates a simple structure suitable for cost-effective and versatile applications.
format Preprint
id arxiv_https___arxiv_org_abs_2502_11512
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Triaxial Alignment Magnetometer Utilizing Free-Spin Precession in the Geomagnetic Range
Jin, Ge
Shi, Tao
Zou, Sheng
Atomic Physics
Applied Physics
In this paper, we present a triaxial alignment magnetometer based on free-spin precession deployed in the geomagnetic range. Existing vector measurement methods often require complex optical setups, heating structures, and laser modulation. This study addresses this challenge by employing a linearly polarized probe beam to induce atomic alignment and subsequently detecting the optical polarization rotation caused by the pulsed radio frequency field. The experiment is conducted in a paraffin-coated cell without buffer gas at room temperature, containing rubidium with natural abundance. We report triaxial measurements with a static magnetic field amplitude of approximately 50 $μ{\text{T}}$ (close to Earth's magnetic field), where the noise levels for each axis are approximately 5.3 ${\text{pT/}}\sqrt{\text{Hz}}$, 4.7 ${\text{pT/}}\sqrt{\text{Hz}}$, and 9.3 ${\text{pT/}}\sqrt{\text{Hz}}$ respectively. The proposed method demonstrates a simple structure suitable for cost-effective and versatile applications.
title Triaxial Alignment Magnetometer Utilizing Free-Spin Precession in the Geomagnetic Range
topic Atomic Physics
Applied Physics
url https://arxiv.org/abs/2502.11512