Breaking the Low Concentration Barrier of Single-Molecule Fluorescence Quantification to the Sub-Picomolar Range

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Veedu, Malavika Kayyil, Wenger, Jérôme
Format: Preprint
Publié: 2025
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866929718020800512
author Veedu, Malavika Kayyil
Wenger, Jérôme
author_facet Veedu, Malavika Kayyil
Wenger, Jérôme
contents Single-molecule fluorescence techniques provide exceptional sensitivity to probe biomolecular interactions. However, their application to accurately quantify analytes at the picomolar concentrations relevant for biosensing remains challenged by a severe degradation in the signal-to-background ratio. This so-called 'low concentration barrier' is a major factor hindering the broad application of single-molecule fluorescence to biosensing. Here we break into the low concentration limit while keeping intact the confocal microscope architecture and without requiring complex microfluidics or preconcentration stages. Using fluorescence lifetime correlation spectroscopy (FLCS) and adding a diaphragm to the laser excitation beam, we achieve a limit of quantitation (LOQ) down to 0.1 pM, significantly below the state-of-the-art. We identify the physical parameters setting the LOQ and introduce a broadly applicable figure of merit (FoM) that determines the LOQ and allows for a clear comparison between experimental configurations. Our approach preserves the ability to monitor dynamic interactions, diffusion times, and distinguish species in complex mixtures. We illustrate this feature by measuring the biotin-streptavidin association rate constant which is highly challenging to assess quantitatively due to the strong affinity of the biotin-streptavidin interaction. These findings push the boundaries of single-molecule fluorescence detection for biosensing applications at sub-picomolar concentrations with high accuracy and simplified systems.
format Preprint
id arxiv_https___arxiv_org_abs_2502_11675
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Breaking the Low Concentration Barrier of Single-Molecule Fluorescence Quantification to the Sub-Picomolar Range
Veedu, Malavika Kayyil
Wenger, Jérôme
Optics
Single-molecule fluorescence techniques provide exceptional sensitivity to probe biomolecular interactions. However, their application to accurately quantify analytes at the picomolar concentrations relevant for biosensing remains challenged by a severe degradation in the signal-to-background ratio. This so-called 'low concentration barrier' is a major factor hindering the broad application of single-molecule fluorescence to biosensing. Here we break into the low concentration limit while keeping intact the confocal microscope architecture and without requiring complex microfluidics or preconcentration stages. Using fluorescence lifetime correlation spectroscopy (FLCS) and adding a diaphragm to the laser excitation beam, we achieve a limit of quantitation (LOQ) down to 0.1 pM, significantly below the state-of-the-art. We identify the physical parameters setting the LOQ and introduce a broadly applicable figure of merit (FoM) that determines the LOQ and allows for a clear comparison between experimental configurations. Our approach preserves the ability to monitor dynamic interactions, diffusion times, and distinguish species in complex mixtures. We illustrate this feature by measuring the biotin-streptavidin association rate constant which is highly challenging to assess quantitatively due to the strong affinity of the biotin-streptavidin interaction. These findings push the boundaries of single-molecule fluorescence detection for biosensing applications at sub-picomolar concentrations with high accuracy and simplified systems.
title Breaking the Low Concentration Barrier of Single-Molecule Fluorescence Quantification to the Sub-Picomolar Range
topic Optics
url https://arxiv.org/abs/2502.11675