Suppression of heading errors in Bell-Bloom optically pumped free-induction-decay alkali-metal atomic magnetometers

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Liu, Siqi, Wang, Xueke, Zhang, Xiangdong, Xiao, Wei, Sheng, Dong
Natura: Preprint
Pubblicazione: 2025
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866917928857763840
author Liu, Siqi
Wang, Xueke
Zhang, Xiangdong
Xiao, Wei
Sheng, Dong
author_facet Liu, Siqi
Wang, Xueke
Zhang, Xiangdong
Xiao, Wei
Sheng, Dong
contents Heading errors of atomic magnetometers refer to the dependence of measurement results on the sensor orientation with respect to the external magnetic field. There are three main sources of such errors: the light shift effect, the linear nuclear-spin Zeeman effect, and the nonlinear Zeeman effect. In this work, we suppress the former two effects by using the Bell-Bloom optical pumping method and probe the atomic signals while the pumping beam is off, and focus on the heading error induced by nonlinear Zeeman effect while the sensor operates in the geomagnetic field range. We demonstrate several schemes to suppress this remaining heading error within 1 nT using a single magnetometer or a comagnetometer. In the magnetometer system, two schemes are developed to average out the horizontal atomic polarization in space or in time, respectively. In the comagnetometer system, we combine the simultaneously measured Larmor frequencies of two different kinds of alkali atoms to either suppress the heading error or extract the orientation of the pumping beam relative to the bias field.
format Preprint
id arxiv_https___arxiv_org_abs_2502_13414
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Suppression of heading errors in Bell-Bloom optically pumped free-induction-decay alkali-metal atomic magnetometers
Liu, Siqi
Wang, Xueke
Zhang, Xiangdong
Xiao, Wei
Sheng, Dong
Atomic Physics
Heading errors of atomic magnetometers refer to the dependence of measurement results on the sensor orientation with respect to the external magnetic field. There are three main sources of such errors: the light shift effect, the linear nuclear-spin Zeeman effect, and the nonlinear Zeeman effect. In this work, we suppress the former two effects by using the Bell-Bloom optical pumping method and probe the atomic signals while the pumping beam is off, and focus on the heading error induced by nonlinear Zeeman effect while the sensor operates in the geomagnetic field range. We demonstrate several schemes to suppress this remaining heading error within 1 nT using a single magnetometer or a comagnetometer. In the magnetometer system, two schemes are developed to average out the horizontal atomic polarization in space or in time, respectively. In the comagnetometer system, we combine the simultaneously measured Larmor frequencies of two different kinds of alkali atoms to either suppress the heading error or extract the orientation of the pumping beam relative to the bias field.
title Suppression of heading errors in Bell-Bloom optically pumped free-induction-decay alkali-metal atomic magnetometers
topic Atomic Physics
url https://arxiv.org/abs/2502.13414