MAGO-SP: Detection and Correction of Water-Fat Swaps in Magnitude-Only VIBE MRI

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Graf, Robert, Möller, Hendrik, Starck, Sophie, Atad, Matan, Braun, Philipp, Stelter, Jonathan, Peters, Annette, Krist, Lilian, Willich, Stefan N., Völzke, Henry, Bülow, Robin, Berger, Klaus, Pischon, Tobias, Niendorf, Thoralf, Paetzold, Johannes, Karampinos, Dimitrios, Rueckert, Daniel, Kirschke, Jan
Format: Preprint
Veröffentlicht: 2025
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866913700770742272
author Graf, Robert
Möller, Hendrik
Starck, Sophie
Atad, Matan
Braun, Philipp
Stelter, Jonathan
Peters, Annette
Krist, Lilian
Willich, Stefan N.
Völzke, Henry
Bülow, Robin
Berger, Klaus
Pischon, Tobias
Niendorf, Thoralf
Paetzold, Johannes
Karampinos, Dimitrios
Rueckert, Daniel
Kirschke, Jan
author_facet Graf, Robert
Möller, Hendrik
Starck, Sophie
Atad, Matan
Braun, Philipp
Stelter, Jonathan
Peters, Annette
Krist, Lilian
Willich, Stefan N.
Völzke, Henry
Bülow, Robin
Berger, Klaus
Pischon, Tobias
Niendorf, Thoralf
Paetzold, Johannes
Karampinos, Dimitrios
Rueckert, Daniel
Kirschke, Jan
contents Volume Interpolated Breath-Hold Examination (VIBE) MRI generates images suitable for water and fat signal composition estimation. While the two-point VIBE provides water-fat-separated images, the six-point VIBE allows estimation of the effective transversal relaxation rate R2* and the proton density fat fraction (PDFF), which are imaging markers for health and disease. Ambiguity during signal reconstruction can lead to water-fat swaps. This shortcoming challenges the application of VIBE-MRI for automated PDFF analyses of large-scale clinical data and of population studies. This study develops an automated pipeline to detect and correct water-fat swaps in non-contrast-enhanced VIBE images. Our three-step pipeline begins with training a segmentation network to classify volumes as "fat-like" or "water-like," using synthetic water-fat swaps generated by merging fat and water volumes with Perlin noise. Next, a denoising diffusion image-to-image network predicts water volumes as signal priors for correction. Finally, we integrate this prior into a physics-constrained model to recover accurate water and fat signals. Our approach achieves a < 1% error rate in water-fat swap detection for a 6-point VIBE. Notably, swaps disproportionately affect individuals in the Underweight and Class 3 Obesity BMI categories. Our correction algorithm ensures accurate solution selection in chemical phase MRIs, enabling reliable PDFF estimation. This forms a solid technical foundation for automated large-scale population imaging analysis.
format Preprint
id arxiv_https___arxiv_org_abs_2502_14659
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle MAGO-SP: Detection and Correction of Water-Fat Swaps in Magnitude-Only VIBE MRI
Graf, Robert
Möller, Hendrik
Starck, Sophie
Atad, Matan
Braun, Philipp
Stelter, Jonathan
Peters, Annette
Krist, Lilian
Willich, Stefan N.
Völzke, Henry
Bülow, Robin
Berger, Klaus
Pischon, Tobias
Niendorf, Thoralf
Paetzold, Johannes
Karampinos, Dimitrios
Rueckert, Daniel
Kirschke, Jan
Computer Vision and Pattern Recognition
Volume Interpolated Breath-Hold Examination (VIBE) MRI generates images suitable for water and fat signal composition estimation. While the two-point VIBE provides water-fat-separated images, the six-point VIBE allows estimation of the effective transversal relaxation rate R2* and the proton density fat fraction (PDFF), which are imaging markers for health and disease. Ambiguity during signal reconstruction can lead to water-fat swaps. This shortcoming challenges the application of VIBE-MRI for automated PDFF analyses of large-scale clinical data and of population studies. This study develops an automated pipeline to detect and correct water-fat swaps in non-contrast-enhanced VIBE images. Our three-step pipeline begins with training a segmentation network to classify volumes as "fat-like" or "water-like," using synthetic water-fat swaps generated by merging fat and water volumes with Perlin noise. Next, a denoising diffusion image-to-image network predicts water volumes as signal priors for correction. Finally, we integrate this prior into a physics-constrained model to recover accurate water and fat signals. Our approach achieves a < 1% error rate in water-fat swap detection for a 6-point VIBE. Notably, swaps disproportionately affect individuals in the Underweight and Class 3 Obesity BMI categories. Our correction algorithm ensures accurate solution selection in chemical phase MRIs, enabling reliable PDFF estimation. This forms a solid technical foundation for automated large-scale population imaging analysis.
title MAGO-SP: Detection and Correction of Water-Fat Swaps in Magnitude-Only VIBE MRI
topic Computer Vision and Pattern Recognition
url https://arxiv.org/abs/2502.14659