Simulation Studies of the Effect of SiPM Dark Noise on the Performance of a Highly Granular Crystal ECAL

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Rolph, Jack, Liu, Yong, Qi, Baohua, Zhao, Zhiyu
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866910838274654208
author Rolph, Jack
Liu, Yong
Qi, Baohua
Zhao, Zhiyu
author_facet Rolph, Jack
Liu, Yong
Qi, Baohua
Zhao, Zhiyu
contents A proposal for the CEPC ECAL is a highly-granular scintillating crystal design that uses SiPMs to measure physics signals from photons. Radiation damage to the silicon will impair the performance of the calorimeter due to dark noise, which will affect the reconstruction capabilities of the calorimeter system. This paper presents a simulation study assessing the effect of radiation damage of SiPM dark noise on the response from calorimeter to electrons due to changing fluence and temperature. It was observed that dark noise significantly degrades the linearity of response, with up to 45% error in reconstructed energy for a 1 GeV shower at a fluence of $1 \times 10^{10}\mathrm{cm}^{-2}$. The stochastic and noise resolution terms was observed to remain stable, increasing only by 0.2% and 1% respectively in the range $1 \times 10^{7}-1 \times 10^{10}\mathrm{cm}^{-2}$ fluence. Under the assumption of no irradiation, the influence of dark noise with temperature in the normal operating range of the calorimeter system was estimated to be negligible.
format Preprint
id arxiv_https___arxiv_org_abs_2502_15353
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Simulation Studies of the Effect of SiPM Dark Noise on the Performance of a Highly Granular Crystal ECAL
Rolph, Jack
Liu, Yong
Qi, Baohua
Zhao, Zhiyu
Instrumentation and Detectors
High Energy Physics - Experiment
A proposal for the CEPC ECAL is a highly-granular scintillating crystal design that uses SiPMs to measure physics signals from photons. Radiation damage to the silicon will impair the performance of the calorimeter due to dark noise, which will affect the reconstruction capabilities of the calorimeter system. This paper presents a simulation study assessing the effect of radiation damage of SiPM dark noise on the response from calorimeter to electrons due to changing fluence and temperature. It was observed that dark noise significantly degrades the linearity of response, with up to 45% error in reconstructed energy for a 1 GeV shower at a fluence of $1 \times 10^{10}\mathrm{cm}^{-2}$. The stochastic and noise resolution terms was observed to remain stable, increasing only by 0.2% and 1% respectively in the range $1 \times 10^{7}-1 \times 10^{10}\mathrm{cm}^{-2}$ fluence. Under the assumption of no irradiation, the influence of dark noise with temperature in the normal operating range of the calorimeter system was estimated to be negligible.
title Simulation Studies of the Effect of SiPM Dark Noise on the Performance of a Highly Granular Crystal ECAL
topic Instrumentation and Detectors
High Energy Physics - Experiment
url https://arxiv.org/abs/2502.15353