Multiple-Amplifier Sensing Charged-Coupled Device: Model and improvement of the Node Removal Efficiency

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Gimenez, Blas J. Irigoyen, Gamero, Miqueas E., Blanco, Claudio R. Chavez, Lapi, Agustin J., Chierchie, Fernando, Moroni, Guillermo Fernandez, Estrada, Juan, Tiffenberg, Javier, Drlica-Wagner, Alex
Natura: Preprint
Pubblicazione: 2025
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866910839140777984
author Gimenez, Blas J. Irigoyen
Gamero, Miqueas E.
Blanco, Claudio R. Chavez
Lapi, Agustin J.
Chierchie, Fernando
Moroni, Guillermo Fernandez
Estrada, Juan
Tiffenberg, Javier
Drlica-Wagner, Alex
author_facet Gimenez, Blas J. Irigoyen
Gamero, Miqueas E.
Blanco, Claudio R. Chavez
Lapi, Agustin J.
Chierchie, Fernando
Moroni, Guillermo Fernandez
Estrada, Juan
Tiffenberg, Javier
Drlica-Wagner, Alex
contents The Multiple Amplifier Sensing Charge-Coupled Device (MAS-CCD) has emerged as a promising technology for astronomical observation, quantum imaging, and low-energy particle detection due to its ability to reduce the readout noise without increasing the readout time as in its predecessor, the Skipper-CCD, by reading out the same charge packet through multiple inline amplifiers. Previous works identified a new parameter in this sensor, called the Node Removal Inefficiency (NRI), related to inefficiencies in charge transfer and residual charge removal from the output gates after readout. These inefficiencies can lead to distortions in the measured signals similar to those produced by the charge transfer inefficiencies in standard CCDs. This work introduces more details in the mathematical description of the NRI mechanism and provides techniques to quantify its magnitude from the measured data. It also proposes a new operation strategy that significantly reduces its effect with minimal alterations of the timing sequences or voltage settings for the other components of the sensor. The proposed technique is corroborated by experimental results on a sixteen-amplifier MAS-CCD. At the same time, the experimental data demonstrate that this approach minimizes the NRI effect to levels comparable to other sources of distortion the charge transfer inefficiency in scientific devices.
format Preprint
id arxiv_https___arxiv_org_abs_2502_15644
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Multiple-Amplifier Sensing Charged-Coupled Device: Model and improvement of the Node Removal Efficiency
Gimenez, Blas J. Irigoyen
Gamero, Miqueas E.
Blanco, Claudio R. Chavez
Lapi, Agustin J.
Chierchie, Fernando
Moroni, Guillermo Fernandez
Estrada, Juan
Tiffenberg, Javier
Drlica-Wagner, Alex
Instrumentation and Methods for Astrophysics
Instrumentation and Detectors
The Multiple Amplifier Sensing Charge-Coupled Device (MAS-CCD) has emerged as a promising technology for astronomical observation, quantum imaging, and low-energy particle detection due to its ability to reduce the readout noise without increasing the readout time as in its predecessor, the Skipper-CCD, by reading out the same charge packet through multiple inline amplifiers. Previous works identified a new parameter in this sensor, called the Node Removal Inefficiency (NRI), related to inefficiencies in charge transfer and residual charge removal from the output gates after readout. These inefficiencies can lead to distortions in the measured signals similar to those produced by the charge transfer inefficiencies in standard CCDs. This work introduces more details in the mathematical description of the NRI mechanism and provides techniques to quantify its magnitude from the measured data. It also proposes a new operation strategy that significantly reduces its effect with minimal alterations of the timing sequences or voltage settings for the other components of the sensor. The proposed technique is corroborated by experimental results on a sixteen-amplifier MAS-CCD. At the same time, the experimental data demonstrate that this approach minimizes the NRI effect to levels comparable to other sources of distortion the charge transfer inefficiency in scientific devices.
title Multiple-Amplifier Sensing Charged-Coupled Device: Model and improvement of the Node Removal Efficiency