Improving Optics Control and Measurement at RHIC

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Fung, W., Hao, Y., Gu, X., Robert-Demolaize, G.
Natura: Preprint
Pubblicazione: 2025
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866914618380648448
author Fung, W.
Hao, Y.
Gu, X.
Robert-Demolaize, G.
author_facet Fung, W.
Hao, Y.
Gu, X.
Robert-Demolaize, G.
contents Maximizing luminosity requires precise control of the optics function at the interaction point (IP), implying that the location ($s^*$) of the beta function's minimum value ($β^*$) must be moved to the collision location ($s_{IP}$) as much as possible. Accurate optics measurements and reliable control of $s^*$ in both planes are therefore essential for optimal collider performance. During Relativistic Heavy Ion Collider (RHIC) operations in 2024, measurements indicate an average horizontal beta beat of approximately $20\%$ at IP8, accompanied by measurement variation in measured $s^*$ in both planes. In this paper, a sensitivity-matrix-based optics correction scheme is demonstrated to effectively steer the optics toward desired targets using power supply currents of IR quadrupoles in the 8 o'clock interaction region (IR8). In addition, a method for measuring linear optics based on the one-turn map within the interaction regions is developed and systematically compared with established optics measurement methods used in RHIC operations. A comprehensive error analysis is performed for all measurement methods considered. Through these methods, a consistent reduction of $10\%$ beta beat is achieved by moving $s^*_x$ as well as a significant improvement in the reproducibility of $s^*$ measurements in both planes. The techniques demonstrated here will be further developed to support linear optics analysis and control of the future Electron-Ion Collider project.
format Preprint
id arxiv_https___arxiv_org_abs_2502_15847
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Improving Optics Control and Measurement at RHIC
Fung, W.
Hao, Y.
Gu, X.
Robert-Demolaize, G.
Accelerator Physics
Nuclear Experiment
Maximizing luminosity requires precise control of the optics function at the interaction point (IP), implying that the location ($s^*$) of the beta function's minimum value ($β^*$) must be moved to the collision location ($s_{IP}$) as much as possible. Accurate optics measurements and reliable control of $s^*$ in both planes are therefore essential for optimal collider performance. During Relativistic Heavy Ion Collider (RHIC) operations in 2024, measurements indicate an average horizontal beta beat of approximately $20\%$ at IP8, accompanied by measurement variation in measured $s^*$ in both planes. In this paper, a sensitivity-matrix-based optics correction scheme is demonstrated to effectively steer the optics toward desired targets using power supply currents of IR quadrupoles in the 8 o'clock interaction region (IR8). In addition, a method for measuring linear optics based on the one-turn map within the interaction regions is developed and systematically compared with established optics measurement methods used in RHIC operations. A comprehensive error analysis is performed for all measurement methods considered. Through these methods, a consistent reduction of $10\%$ beta beat is achieved by moving $s^*_x$ as well as a significant improvement in the reproducibility of $s^*$ measurements in both planes. The techniques demonstrated here will be further developed to support linear optics analysis and control of the future Electron-Ion Collider project.
title Improving Optics Control and Measurement at RHIC
topic Accelerator Physics
Nuclear Experiment
url https://arxiv.org/abs/2502.15847