Improving Optics Control and Measurement at RHIC
Fuente:
arXiv
Salvato in:
| Autori principali: | , , , |
|---|---|
| Natura: | Preprint |
| Pubblicazione: |
2025
|
| Soggetti: | |
| Accesso online: | |
| Tags: |
Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
|
| _version_ | 1866914618380648448 |
|---|---|
| author | Fung, W. Hao, Y. Gu, X. Robert-Demolaize, G. |
| author_facet | Fung, W. Hao, Y. Gu, X. Robert-Demolaize, G. |
| contents | Maximizing luminosity requires precise control of the optics function at the interaction point (IP), implying that the location ($s^*$) of the beta function's minimum value ($β^*$) must be moved to the collision location ($s_{IP}$) as much as possible. Accurate optics measurements and reliable control of $s^*$ in both planes are therefore essential for optimal collider performance. During Relativistic Heavy Ion Collider (RHIC) operations in 2024, measurements indicate an average horizontal beta beat of approximately $20\%$ at IP8, accompanied by measurement variation in measured $s^*$ in both planes. In this paper, a sensitivity-matrix-based optics correction scheme is demonstrated to effectively steer the optics toward desired targets using power supply currents of IR quadrupoles in the 8 o'clock interaction region (IR8). In addition, a method for measuring linear optics based on the one-turn map within the interaction regions is developed and systematically compared with established optics measurement methods used in RHIC operations. A comprehensive error analysis is performed for all measurement methods considered. Through these methods, a consistent reduction of $10\%$ beta beat is achieved by moving $s^*_x$ as well as a significant improvement in the reproducibility of $s^*$ measurements in both planes. The techniques demonstrated here will be further developed to support linear optics analysis and control of the future Electron-Ion Collider project. |
| format | Preprint |
| id |
arxiv_https___arxiv_org_abs_2502_15847 |
| institution | arXiv |
| publishDate | 2025 |
| record_format | arxiv |
| spellingShingle | Improving Optics Control and Measurement at RHIC Fung, W. Hao, Y. Gu, X. Robert-Demolaize, G. Accelerator Physics Nuclear Experiment Maximizing luminosity requires precise control of the optics function at the interaction point (IP), implying that the location ($s^*$) of the beta function's minimum value ($β^*$) must be moved to the collision location ($s_{IP}$) as much as possible. Accurate optics measurements and reliable control of $s^*$ in both planes are therefore essential for optimal collider performance. During Relativistic Heavy Ion Collider (RHIC) operations in 2024, measurements indicate an average horizontal beta beat of approximately $20\%$ at IP8, accompanied by measurement variation in measured $s^*$ in both planes. In this paper, a sensitivity-matrix-based optics correction scheme is demonstrated to effectively steer the optics toward desired targets using power supply currents of IR quadrupoles in the 8 o'clock interaction region (IR8). In addition, a method for measuring linear optics based on the one-turn map within the interaction regions is developed and systematically compared with established optics measurement methods used in RHIC operations. A comprehensive error analysis is performed for all measurement methods considered. Through these methods, a consistent reduction of $10\%$ beta beat is achieved by moving $s^*_x$ as well as a significant improvement in the reproducibility of $s^*$ measurements in both planes. The techniques demonstrated here will be further developed to support linear optics analysis and control of the future Electron-Ion Collider project. |
| title | Improving Optics Control and Measurement at RHIC |
| topic | Accelerator Physics Nuclear Experiment |
| url | https://arxiv.org/abs/2502.15847 |