Imaging and Spectral Performance of a Wide-gap CdTe Double-Sided Strip Detector

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Nagasawa, Shunsaku, Minami, Takahiro, Watanabe, Shin, Takahashi, Tadayuki
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866929761207451648
author Nagasawa, Shunsaku
Minami, Takahiro
Watanabe, Shin
Takahashi, Tadayuki
author_facet Nagasawa, Shunsaku
Minami, Takahiro
Watanabe, Shin
Takahashi, Tadayuki
contents The fourth flight of the Focusing Optics X-ray Solar Imager sounding rocket experiment (FOXSI-4) aimed to achieve the first imaging spectroscopic observations of mid-to-large class ( >= GOES C5 class) solar flares, in contrast to the previous three flights that targeted relatively quiet regions of the Sun. To meet the emerging requirements for hard X-ray focal plane detectors for providing simultaneous diagnostics of spectrally (<1 keV FWHM) and spatially (<50 um) separated coronal and chromospheric emissions from solar flares, we developed a new strip-configuration detector called the wide-gap CdTe semiconductor double-sided strip detector (CdTe-DSD). The wide-gap CdTe-DSD employs a unique design principle to enhance position resolution. This enhancement is realized by expanding the gaps between electrodes to induce charge-sharing across adjacent strip electrodes and using this sharing energy information for position reconstruction to a level finer than the strip-pitch. However, the detector response becomes complex and requires consideration of various factors, such as the charge loss due to wider gaps and the dependence on the depth of photon interaction. Thus, we developed an energy reconstruction method that fully leverages the energy information between adjacent strips and from both the cathode and anode sides, achieving an energy resolution of 0.75 keV (FWHM) at 14 keV. Furthermore, we conducted an X-ray scanning experiment using a synchrotron beam at Spring-8 to evaluate the detector response with a fine scale of 10 um. Based on these results, we established a sub-strip position reconstruction method, demonstrating that X-rays interacting at the center of the gap can be determined with an accuracy of 20 um, and even those at the strip center can be determined with an accuracy of 50 um.
format Preprint
id arxiv_https___arxiv_org_abs_2502_15899
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Imaging and Spectral Performance of a Wide-gap CdTe Double-Sided Strip Detector
Nagasawa, Shunsaku
Minami, Takahiro
Watanabe, Shin
Takahashi, Tadayuki
Instrumentation and Methods for Astrophysics
Solar and Stellar Astrophysics
High Energy Physics - Experiment
Instrumentation and Detectors
The fourth flight of the Focusing Optics X-ray Solar Imager sounding rocket experiment (FOXSI-4) aimed to achieve the first imaging spectroscopic observations of mid-to-large class ( >= GOES C5 class) solar flares, in contrast to the previous three flights that targeted relatively quiet regions of the Sun. To meet the emerging requirements for hard X-ray focal plane detectors for providing simultaneous diagnostics of spectrally (<1 keV FWHM) and spatially (<50 um) separated coronal and chromospheric emissions from solar flares, we developed a new strip-configuration detector called the wide-gap CdTe semiconductor double-sided strip detector (CdTe-DSD). The wide-gap CdTe-DSD employs a unique design principle to enhance position resolution. This enhancement is realized by expanding the gaps between electrodes to induce charge-sharing across adjacent strip electrodes and using this sharing energy information for position reconstruction to a level finer than the strip-pitch. However, the detector response becomes complex and requires consideration of various factors, such as the charge loss due to wider gaps and the dependence on the depth of photon interaction. Thus, we developed an energy reconstruction method that fully leverages the energy information between adjacent strips and from both the cathode and anode sides, achieving an energy resolution of 0.75 keV (FWHM) at 14 keV. Furthermore, we conducted an X-ray scanning experiment using a synchrotron beam at Spring-8 to evaluate the detector response with a fine scale of 10 um. Based on these results, we established a sub-strip position reconstruction method, demonstrating that X-rays interacting at the center of the gap can be determined with an accuracy of 20 um, and even those at the strip center can be determined with an accuracy of 50 um.
title Imaging and Spectral Performance of a Wide-gap CdTe Double-Sided Strip Detector
topic Instrumentation and Methods for Astrophysics
Solar and Stellar Astrophysics
High Energy Physics - Experiment
Instrumentation and Detectors
url https://arxiv.org/abs/2502.15899