Hauptverfasser: Siano, Gabriel, Mora, Sofia, Schenone, Agustina, Giovanini, Leonardo
Format: Preprint
Veröffentlicht: 2025
Schlagworte:
Online-Zugang:https://arxiv.org/abs/2502.19431
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866917938758418432
author Siano, Gabriel
Mora, Sofia
Schenone, Agustina
Giovanini, Leonardo
author_facet Siano, Gabriel
Mora, Sofia
Schenone, Agustina
Giovanini, Leonardo
contents Sequential registering of fluorescence signals in conventional Excitation-Emission Matrices (EEMs), followed by modeling based on multilinear properties of the data, requires stable fluorophore concentrations throughout the acquisition of each EEM. Rapid concentration changes, as seen in chromatography or certain kinetics, can disrupt the conventional bilinearity of EEMs. This deviation depends on the relative rates of concentration changes versus spectral scanning speeds. Although entire scans can be slow, individual data points are acquired almost instantaneously, maintaining linear dependencies. Within specific time intervals, concentrations can be assumed constant. By using time-based localization, partial EEM data can be organized into partially filled cubes that allow for the correct modeling of third-order data. Additionally, Multivariate Curve Resolution requires reshaping operations. Two third-order datasets were analyzed using a time-assisted MCR implementation, following a strategy similar to one reported for chromatographic data (LC-EEM) with Parallel Factor Analysis. The second dataset comes from Diclofenac reaction kinetics (Kin-EEM). The results suggest that time-assisted MCR resolves such data effectively. The solutions found were similar to those obtained when processing the same data as cubes. Predictions from calibration models based on MCR results were comparable to those obtained when deriving higher order models from the same data. High degrees of similarity were achieved between resolved and reference spectral profiles. Both chromatographic and kinetic profiles were accurate and physically meaningful. The proposed strategy highlights the potential of incorporating time-based localization to enhance the analysis of fluorescence data in dynamic systems.
format Preprint
id arxiv_https___arxiv_org_abs_2502_19431
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Sequential acquisition of fluorescence signals with changing fluorophore concentrations. Multivariate Curve Resolution with time measurements assistance
Siano, Gabriel
Mora, Sofia
Schenone, Agustina
Giovanini, Leonardo
Medical Physics
Biological Physics
Instrumentation and Detectors
Sequential registering of fluorescence signals in conventional Excitation-Emission Matrices (EEMs), followed by modeling based on multilinear properties of the data, requires stable fluorophore concentrations throughout the acquisition of each EEM. Rapid concentration changes, as seen in chromatography or certain kinetics, can disrupt the conventional bilinearity of EEMs. This deviation depends on the relative rates of concentration changes versus spectral scanning speeds. Although entire scans can be slow, individual data points are acquired almost instantaneously, maintaining linear dependencies. Within specific time intervals, concentrations can be assumed constant. By using time-based localization, partial EEM data can be organized into partially filled cubes that allow for the correct modeling of third-order data. Additionally, Multivariate Curve Resolution requires reshaping operations. Two third-order datasets were analyzed using a time-assisted MCR implementation, following a strategy similar to one reported for chromatographic data (LC-EEM) with Parallel Factor Analysis. The second dataset comes from Diclofenac reaction kinetics (Kin-EEM). The results suggest that time-assisted MCR resolves such data effectively. The solutions found were similar to those obtained when processing the same data as cubes. Predictions from calibration models based on MCR results were comparable to those obtained when deriving higher order models from the same data. High degrees of similarity were achieved between resolved and reference spectral profiles. Both chromatographic and kinetic profiles were accurate and physically meaningful. The proposed strategy highlights the potential of incorporating time-based localization to enhance the analysis of fluorescence data in dynamic systems.
title Sequential acquisition of fluorescence signals with changing fluorophore concentrations. Multivariate Curve Resolution with time measurements assistance
topic Medical Physics
Biological Physics
Instrumentation and Detectors
url https://arxiv.org/abs/2502.19431