contents The virtual synchronous generator (VSG), with the analogous nonlinear power-angle relationship to the synchronous generator (SG), has attracted much attention as a promising solution for converter-based power systems. In this paper, a large signal model of the grid-connected VSG is first established. The trajectory reversing method (TRM) is then introduced to estimate the domain of attraction (DOA) of VSG. Subsequently, the transient instability mechanism is revealed in detail based on the estimated DOA boundary. The impacts of system parameters on the DOA range are further investigated. It is found that loss of synchronization (LOS) occurs if the system trajectory lies outside the post-fault DOA range. In scenarios where no equilibrium points exist after a grid fault, system stability can be reestablished only when the fault clearing angle (FCA) does not exceed the critical clearing angle (CCA). Finally, the CCA derived from the DOA and that from the conventional equal area criteria (EAC) are compared. The results show that CCA obtained by our solution has a higher accuracy. Time-domain simulations are performed to verify the effectiveness of the proposed transient stability analysis method of grid-connected VSG.
format Preprint
id arxiv_https___arxiv_org_abs_2502_19728
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Transient Stability Analysis and Fault Clearing Angle Estimation of VSG Based on Domain of Attraction Estimated by Trajectory Reversing Method
Lyu, Jiayue
Fang, Tianzhi
Lin, Zhiheng
Han, Jingxue
Zhu, Yantao
Systems and Control
The virtual synchronous generator (VSG), with the analogous nonlinear power-angle relationship to the synchronous generator (SG), has attracted much attention as a promising solution for converter-based power systems. In this paper, a large signal model of the grid-connected VSG is first established. The trajectory reversing method (TRM) is then introduced to estimate the domain of attraction (DOA) of VSG. Subsequently, the transient instability mechanism is revealed in detail based on the estimated DOA boundary. The impacts of system parameters on the DOA range are further investigated. It is found that loss of synchronization (LOS) occurs if the system trajectory lies outside the post-fault DOA range. In scenarios where no equilibrium points exist after a grid fault, system stability can be reestablished only when the fault clearing angle (FCA) does not exceed the critical clearing angle (CCA). Finally, the CCA derived from the DOA and that from the conventional equal area criteria (EAC) are compared. The results show that CCA obtained by our solution has a higher accuracy. Time-domain simulations are performed to verify the effectiveness of the proposed transient stability analysis method of grid-connected VSG.
title Transient Stability Analysis and Fault Clearing Angle Estimation of VSG Based on Domain of Attraction Estimated by Trajectory Reversing Method
topic Systems and Control
url https://arxiv.org/abs/2502.19728