Lifted Frequency-Domain Identification of Closed-Loop Multirate Systems: Applied to Dual-Stage Actuator Hard Disk Drives

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: van Haren, Max, Mae, Masahiro, Blanken, Lennart, Oomen, Tom
Format: Preprint
Publié: 2025
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866909572548001792
author van Haren, Max
Mae, Masahiro
Blanken, Lennart
Oomen, Tom
author_facet van Haren, Max
Mae, Masahiro
Blanken, Lennart
Oomen, Tom
contents Frequency-domain representations are crucial for the design and performance evaluation of controllers in multirate systems, specifically to address intersample performance. The aim of this paper is to develop an effective frequency-domain system identification technique for closed-loop multirate systems using solely slow-rate output measurements. By indirect identification of multivariable time-invariant representations through lifting, in combination with local modeling techniques, the multirate system is effectively identified. The developed method is capable of accurate identification of closed-loop multirate systems within a single identification experiment, using fast-rate excitation and inputs, and slow-rate outputs. Finally, the developed framework is validated using a benchmark problem consisting of a multivariable dual-stage actuator from a hard disk drive, demonstrating its applicability and accuracy.
format Preprint
id arxiv_https___arxiv_org_abs_2502_21065
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Lifted Frequency-Domain Identification of Closed-Loop Multirate Systems: Applied to Dual-Stage Actuator Hard Disk Drives
van Haren, Max
Mae, Masahiro
Blanken, Lennart
Oomen, Tom
Systems and Control
Frequency-domain representations are crucial for the design and performance evaluation of controllers in multirate systems, specifically to address intersample performance. The aim of this paper is to develop an effective frequency-domain system identification technique for closed-loop multirate systems using solely slow-rate output measurements. By indirect identification of multivariable time-invariant representations through lifting, in combination with local modeling techniques, the multirate system is effectively identified. The developed method is capable of accurate identification of closed-loop multirate systems within a single identification experiment, using fast-rate excitation and inputs, and slow-rate outputs. Finally, the developed framework is validated using a benchmark problem consisting of a multivariable dual-stage actuator from a hard disk drive, demonstrating its applicability and accuracy.
title Lifted Frequency-Domain Identification of Closed-Loop Multirate Systems: Applied to Dual-Stage Actuator Hard Disk Drives
topic Systems and Control
url https://arxiv.org/abs/2502.21065