Development of High-Sensitivity Radon Emanation Measurement Systems with Surface Treatment Optimization

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Wu, Yuan, Si, Lin, Qian, Zhicheng, Yun, Youhui, Meng, Yue, Liu, Jianglai, Gao, Zhixing, Wang, Hao, Wu, Liangyu, Liang, Yuanzi
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866916817682825216
author Wu, Yuan
Si, Lin
Qian, Zhicheng
Yun, Youhui
Meng, Yue
Liu, Jianglai
Gao, Zhixing
Wang, Hao
Wu, Liangyu
Liang, Yuanzi
author_facet Wu, Yuan
Si, Lin
Qian, Zhicheng
Yun, Youhui
Meng, Yue
Liu, Jianglai
Gao, Zhixing
Wang, Hao
Wu, Liangyu
Liang, Yuanzi
contents Radon and its progenies are significant sources of background in rare event detection experiments, including dark matter searches like the PandaX-4T experiment and other rare decay studies such as neutrinoless double beta decay (NLDBD). In order to measure and control radon emanation for these experiments, we have developed two specialized radon measurement systems: a radon emanation measurement system suitable for small-sized samples with a blank rate of $0.03 \pm 0.01$ mBq in the 12.3 L counting chamber, and a radon trap system designed for large-volume samples using low-temperature radon trapping techniques, which improves the sensitivity by a factor of 30 with 1 standard liter per minute (slpm) gas flow and 6 hours trapping time. To boost the detection sensitivity, various surface treatments of the chambers were investigated, including mechanical polishing, electrochemical polishing, and mirror polishing, which reveals that smoother surfaces lead to lower radon emanation rates. In addition, treatments such as applying epoxy coating and covering with aluminized Mylar to stainless steel chambers can also reduce the radon emanation by ($90 \pm 7)\%$ and ($60 \pm 12)\%$, respectively.
format Preprint
id arxiv_https___arxiv_org_abs_2503_00739
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Development of High-Sensitivity Radon Emanation Measurement Systems with Surface Treatment Optimization
Wu, Yuan
Si, Lin
Qian, Zhicheng
Yun, Youhui
Meng, Yue
Liu, Jianglai
Gao, Zhixing
Wang, Hao
Wu, Liangyu
Liang, Yuanzi
Instrumentation and Detectors
High Energy Physics - Experiment
Radon and its progenies are significant sources of background in rare event detection experiments, including dark matter searches like the PandaX-4T experiment and other rare decay studies such as neutrinoless double beta decay (NLDBD). In order to measure and control radon emanation for these experiments, we have developed two specialized radon measurement systems: a radon emanation measurement system suitable for small-sized samples with a blank rate of $0.03 \pm 0.01$ mBq in the 12.3 L counting chamber, and a radon trap system designed for large-volume samples using low-temperature radon trapping techniques, which improves the sensitivity by a factor of 30 with 1 standard liter per minute (slpm) gas flow and 6 hours trapping time. To boost the detection sensitivity, various surface treatments of the chambers were investigated, including mechanical polishing, electrochemical polishing, and mirror polishing, which reveals that smoother surfaces lead to lower radon emanation rates. In addition, treatments such as applying epoxy coating and covering with aluminized Mylar to stainless steel chambers can also reduce the radon emanation by ($90 \pm 7)\%$ and ($60 \pm 12)\%$, respectively.
title Development of High-Sensitivity Radon Emanation Measurement Systems with Surface Treatment Optimization
topic Instrumentation and Detectors
High Energy Physics - Experiment
url https://arxiv.org/abs/2503.00739