Asymmetrical cavity design that bypasses mode mixings in axion haloscope experiments

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Ko, Byeong Rok, Yi, Andrew K.
Natura: Preprint
Pubblicazione: 2025
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866916789636562944
author Ko, Byeong Rok
Yi, Andrew K.
author_facet Ko, Byeong Rok
Yi, Andrew K.
contents Microwave cavities used in axion haloscope experiments typically employ a tuning rod as a means to widen the range of resonance frequencies at which it is sensitive to axion-to-photon conversion. A realistic tuning mechanism requires a gap between the cavity end caps and the tuning rod to ensure movement, and causes some modes to hybridize with the resonant mode that is being tracked for the experiment. These so-called mode mixings lead to gaps in the frequency range that practically lose sensitivity to axions. In order to solve this problem, we present a cavity design which, for two tuning rod configurations corresponding to a lower and higher frequency range, have a dielectric rod inserted at a specific location that makes the cavity asymmetrical. Moving the tuning rod closer to the dielectric insert changes the location and frequency of the mode mixing compared to when it is farther away from it. This design is easily realizable in practical experiments and makes possible an axion dark matter search with minimal loss in sensitivity due to mode mixings. We also show that the same design has the same desired effect when cavity dimensions are scaled down to be smaller and are at higher resonance frequencies.
format Preprint
id arxiv_https___arxiv_org_abs_2503_01108
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Asymmetrical cavity design that bypasses mode mixings in axion haloscope experiments
Ko, Byeong Rok
Yi, Andrew K.
High Energy Physics - Experiment
High Energy Physics - Phenomenology
Instrumentation and Detectors
Microwave cavities used in axion haloscope experiments typically employ a tuning rod as a means to widen the range of resonance frequencies at which it is sensitive to axion-to-photon conversion. A realistic tuning mechanism requires a gap between the cavity end caps and the tuning rod to ensure movement, and causes some modes to hybridize with the resonant mode that is being tracked for the experiment. These so-called mode mixings lead to gaps in the frequency range that practically lose sensitivity to axions. In order to solve this problem, we present a cavity design which, for two tuning rod configurations corresponding to a lower and higher frequency range, have a dielectric rod inserted at a specific location that makes the cavity asymmetrical. Moving the tuning rod closer to the dielectric insert changes the location and frequency of the mode mixing compared to when it is farther away from it. This design is easily realizable in practical experiments and makes possible an axion dark matter search with minimal loss in sensitivity due to mode mixings. We also show that the same design has the same desired effect when cavity dimensions are scaled down to be smaller and are at higher resonance frequencies.
title Asymmetrical cavity design that bypasses mode mixings in axion haloscope experiments
topic High Energy Physics - Experiment
High Energy Physics - Phenomenology
Instrumentation and Detectors
url https://arxiv.org/abs/2503.01108