Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Rivera-Aguilar, Carlos Manuel, Mursa, Andrei, Carlé, Clément, Friedt, Jean-Michel, Klinger, Emmanuel, Hafiz, Moustafa Abdel, Passilly, Nicolas, Boudot, Rodolphe
Format: Preprint
Veröffentlicht: 2025
Schlagworte:
Online-Zugang:https://arxiv.org/abs/2503.01681
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866917943953063936
author Rivera-Aguilar, Carlos Manuel
Mursa, Andrei
Carlé, Clément
Friedt, Jean-Michel
Klinger, Emmanuel
Hafiz, Moustafa Abdel
Passilly, Nicolas
Boudot, Rodolphe
author_facet Rivera-Aguilar, Carlos Manuel
Mursa, Andrei
Carlé, Clément
Friedt, Jean-Michel
Klinger, Emmanuel
Hafiz, Moustafa Abdel
Passilly, Nicolas
Boudot, Rodolphe
contents We present a coherent-population trapping (CPT) microcell atomic clock using symmetric auto-balanced Ramsey (SABR) spectroscopy. The pulsed SABR sequence is applied through direct current-based power modulation of the vertical-cavity surface-emitting laser, eliminating the need for an external optical shutter and enabling compatibility with fully-integrated clocks. The sequence is controlled by a single FPGA-based digital electronics board. A key aspect of proper clock operation was the implementation of a real-time tracking of the atomic signal detection window. The clock frequency dependence on laser power, microwave power, laser frequency, and timing of the detection window has been measured, obtaining sensitivity coefficients lower than those obtained with Ramsey-CPT spectroscopy. The Allan deviation of the SABR-CPT clock, based on a microfabricated cell with low-permeation glass windows, is 1.1~$\times$~10$^{-9}$ at 1~s and averages down to the low 10$^{-12}$ range at 1 day integration time. These results pave the way towards the development of Ramsey-CPT chip-scale atomic clocks with enhanced timekeeping performances.
format Preprint
id arxiv_https___arxiv_org_abs_2503_01681
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Microcell CPT atomic clock using laser current-actuated power modulation with 10$^{-12}$ range stability at 1 day
Rivera-Aguilar, Carlos Manuel
Mursa, Andrei
Carlé, Clément
Friedt, Jean-Michel
Klinger, Emmanuel
Hafiz, Moustafa Abdel
Passilly, Nicolas
Boudot, Rodolphe
Atomic Physics
We present a coherent-population trapping (CPT) microcell atomic clock using symmetric auto-balanced Ramsey (SABR) spectroscopy. The pulsed SABR sequence is applied through direct current-based power modulation of the vertical-cavity surface-emitting laser, eliminating the need for an external optical shutter and enabling compatibility with fully-integrated clocks. The sequence is controlled by a single FPGA-based digital electronics board. A key aspect of proper clock operation was the implementation of a real-time tracking of the atomic signal detection window. The clock frequency dependence on laser power, microwave power, laser frequency, and timing of the detection window has been measured, obtaining sensitivity coefficients lower than those obtained with Ramsey-CPT spectroscopy. The Allan deviation of the SABR-CPT clock, based on a microfabricated cell with low-permeation glass windows, is 1.1~$\times$~10$^{-9}$ at 1~s and averages down to the low 10$^{-12}$ range at 1 day integration time. These results pave the way towards the development of Ramsey-CPT chip-scale atomic clocks with enhanced timekeeping performances.
title Microcell CPT atomic clock using laser current-actuated power modulation with 10$^{-12}$ range stability at 1 day
topic Atomic Physics
url https://arxiv.org/abs/2503.01681