Parameter estimation in fluid flow models from undersampled frequency space data

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Löcke, Miriam, van Ooij, Pim, Bertoglio, Cristóbal
Natura: Preprint
Pubblicazione: 2025
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866912752116695040
author Löcke, Miriam
van Ooij, Pim
Bertoglio, Cristóbal
author_facet Löcke, Miriam
van Ooij, Pim
Bertoglio, Cristóbal
contents 4D Flow MRI is the state of the art technique for measuring blood flow, and it provides valuable information for inverse problems in the cardiovascular system. However, 4D Flow MRI has a very long acquisition time, straining healthcare resources and inconveniencing patients. Due to this, usually only a part of the frequency space is acquired, where then further assumptions need to be made in order to obtain an image. Inverse problems from 4D Flow MRI data have the potential to compute clinically relevant quantities without the need for invasive procedures, and/or expanding the set of biomarkers for a more accurate diagnosis. However, reconstructing MRI measurements with Compressed Sensing techniques introduces artifacts and inaccuracies, which can compromise the results of the inverse problems. Additionally, there is a high number of different sampling patterns available, and it is often unclear which of them is preferable. Here, we present a parameter estimation problem directly using highly undersampled frequency space measurements. This problem is numerically solved by a Reduced-Order Unscented Kalman Filter (ROUKF). We show that this results in more accurate parameter estimation for boundary conditions in a synthetic aortic blood flow than using measurements reconstructed with Compressed Sensing. We also compare different sampling patterns, demonstrating how the quality of the parameter estimation depends on the choice of the sampling pattern. The results show a considerably higher accuracy than an inverse problem using velocity measurements reconstructed via compressed sensing. Finally, we confirm these findings on real MRI data from a mechanical phantom.
format Preprint
id arxiv_https___arxiv_org_abs_2503_04092
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Parameter estimation in fluid flow models from undersampled frequency space data
Löcke, Miriam
van Ooij, Pim
Bertoglio, Cristóbal
Numerical Analysis
4D Flow MRI is the state of the art technique for measuring blood flow, and it provides valuable information for inverse problems in the cardiovascular system. However, 4D Flow MRI has a very long acquisition time, straining healthcare resources and inconveniencing patients. Due to this, usually only a part of the frequency space is acquired, where then further assumptions need to be made in order to obtain an image. Inverse problems from 4D Flow MRI data have the potential to compute clinically relevant quantities without the need for invasive procedures, and/or expanding the set of biomarkers for a more accurate diagnosis. However, reconstructing MRI measurements with Compressed Sensing techniques introduces artifacts and inaccuracies, which can compromise the results of the inverse problems. Additionally, there is a high number of different sampling patterns available, and it is often unclear which of them is preferable. Here, we present a parameter estimation problem directly using highly undersampled frequency space measurements. This problem is numerically solved by a Reduced-Order Unscented Kalman Filter (ROUKF). We show that this results in more accurate parameter estimation for boundary conditions in a synthetic aortic blood flow than using measurements reconstructed with Compressed Sensing. We also compare different sampling patterns, demonstrating how the quality of the parameter estimation depends on the choice of the sampling pattern. The results show a considerably higher accuracy than an inverse problem using velocity measurements reconstructed via compressed sensing. Finally, we confirm these findings on real MRI data from a mechanical phantom.
title Parameter estimation in fluid flow models from undersampled frequency space data
topic Numerical Analysis
url https://arxiv.org/abs/2503.04092