Using the XMM-Newton small window mode to investigate systematic uncertainties in the particle background of X-ray charge-coupled device detectors

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Schellenberger, Gerrit, Kraft, Ralph, Nulsen, Paul, Miller, Eric D., Bautz, Marshall W., Grant, Catherine E., Wilkins, Dan, Allen, Steven, Molendi, Silvano, Burrows, David N., Falcone, Abraham D., Fioretti, Valentina, Foster, Richard F., Hall, David, Hubbard, Michael W. J., Perinati, Emanuele, Poliszczuk, Artem, Rau, Arne, Sarkar, Arnab, Schneider, Benjamin
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866910881610203136
author Schellenberger, Gerrit
Kraft, Ralph
Nulsen, Paul
Miller, Eric D.
Bautz, Marshall W.
Grant, Catherine E.
Wilkins, Dan
Allen, Steven
Molendi, Silvano
Burrows, David N.
Falcone, Abraham D.
Fioretti, Valentina
Foster, Richard F.
Hall, David
Hubbard, Michael W. J.
Perinati, Emanuele
Poliszczuk, Artem
Rau, Arne
Sarkar, Arnab
Schneider, Benjamin
author_facet Schellenberger, Gerrit
Kraft, Ralph
Nulsen, Paul
Miller, Eric D.
Bautz, Marshall W.
Grant, Catherine E.
Wilkins, Dan
Allen, Steven
Molendi, Silvano
Burrows, David N.
Falcone, Abraham D.
Fioretti, Valentina
Foster, Richard F.
Hall, David
Hubbard, Michael W. J.
Perinati, Emanuele
Poliszczuk, Artem
Rau, Arne
Sarkar, Arnab
Schneider, Benjamin
contents The level and uncertainty of the particle induced background in CCD detectors plays a crucial role for future X-ray instruments, such as the Wide Field Imager (WFI) onboard Athena. To mitigate the background systematic uncertainties, which will limit the Athena science goals, we aim to understand the relationship between the energetic charged particles interacting in the detector and satellite, and the instrumental science background to an unprecedented level. These particles produce easily identified "cosmic-ray tracks" along with less easily identified signals produced by secondary particles, e.g., X-rays generated by particle interactions with the instrument and indistinguishable from genuine sky X-rays. We utilize the Small Window Mode of the PN camera onboard XMM-Newton to understand the time, spatial and energy dependence of the various background components, particularly the particle induced background. While the distribution of particle events follows expected detector readout patterns, we find a particle track length distribution inconsistent with the simple, isotropic model. We also find that the detector mode-specific readout results in a shifted Cu fluorescent line. We illustrate that on long timescales the variability of the particle background correlates well with the solar cycle. This 20-year lightcurve, can be reproduced by a particle detector onboard Chandra, the HRC anti-coincidence shield. We conclude that the self-anti-coincidence method of removing X-ray-like events near detected particle tracks in the same frame can be optimized with the inclusion of additional information, such as the energy of the X-ray. The results presented here are relevant for any future pixelated X-ray imaging detector, and could allow the WFI to probe to truly faint X-ray surface brightness.
format Preprint
id arxiv_https___arxiv_org_abs_2503_04682
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Using the XMM-Newton small window mode to investigate systematic uncertainties in the particle background of X-ray charge-coupled device detectors
Schellenberger, Gerrit
Kraft, Ralph
Nulsen, Paul
Miller, Eric D.
Bautz, Marshall W.
Grant, Catherine E.
Wilkins, Dan
Allen, Steven
Molendi, Silvano
Burrows, David N.
Falcone, Abraham D.
Fioretti, Valentina
Foster, Richard F.
Hall, David
Hubbard, Michael W. J.
Perinati, Emanuele
Poliszczuk, Artem
Rau, Arne
Sarkar, Arnab
Schneider, Benjamin
Instrumentation and Methods for Astrophysics
The level and uncertainty of the particle induced background in CCD detectors plays a crucial role for future X-ray instruments, such as the Wide Field Imager (WFI) onboard Athena. To mitigate the background systematic uncertainties, which will limit the Athena science goals, we aim to understand the relationship between the energetic charged particles interacting in the detector and satellite, and the instrumental science background to an unprecedented level. These particles produce easily identified "cosmic-ray tracks" along with less easily identified signals produced by secondary particles, e.g., X-rays generated by particle interactions with the instrument and indistinguishable from genuine sky X-rays. We utilize the Small Window Mode of the PN camera onboard XMM-Newton to understand the time, spatial and energy dependence of the various background components, particularly the particle induced background. While the distribution of particle events follows expected detector readout patterns, we find a particle track length distribution inconsistent with the simple, isotropic model. We also find that the detector mode-specific readout results in a shifted Cu fluorescent line. We illustrate that on long timescales the variability of the particle background correlates well with the solar cycle. This 20-year lightcurve, can be reproduced by a particle detector onboard Chandra, the HRC anti-coincidence shield. We conclude that the self-anti-coincidence method of removing X-ray-like events near detected particle tracks in the same frame can be optimized with the inclusion of additional information, such as the energy of the X-ray. The results presented here are relevant for any future pixelated X-ray imaging detector, and could allow the WFI to probe to truly faint X-ray surface brightness.
title Using the XMM-Newton small window mode to investigate systematic uncertainties in the particle background of X-ray charge-coupled device detectors
topic Instrumentation and Methods for Astrophysics
url https://arxiv.org/abs/2503.04682